Installation instructions, only for experts

5.12. Remote start

!
The remote start function is deactivated ex-works. When the remote
start function is activated when starting up the unit for the fi rst time,
the sauna control unit may only be used for operating and regulating
a sauna heater which has been certifi ed as satisfying the combustion
test described in paragraph 19.101 of EN 60335-2-53. Alternatively, the
corresponding safety shut-off device may be installed in, or above, the
sauna heater. Activation must be carried out by an electrician (see 8.4.
Activating/deactivating the remote start function on page 30).
The remote start device is connected using terminals "S", "B" and "C". "S" stands for
sauna mode and "C" for evaporator mode. "B" is a +24 V DC output. The preferred
operating mode must be activated using a switch or actuator on the terminal.

5.13. Status output

Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.

5.14. Finishing installation

1. Connect the earth conductor for the power supply cable and all devices to
the earth rail h.
2. Place the cover of the housing on the upper edge of the junction box.
3. Push the clip locks inwards lightly, and turn the cover of the housing down-
wards until it engages audibly.