● Optional dimmer function (up to 500 W) or activation (up to 3.5 kW) for an
additional output.
The additional output has no excess temperature fuse. For this reason only
intrinsically safe devices should be operated on the additional output.
– If infrared heaters are connected to the additional output, these must
have an excess temperature fuse. We recommend using the following
infrared heaters:
● DIR-350-R, WIR-350-R, DIR-500-R, WIR-500-R, DIR-750-R,
WIR-750-R, DIR-1300-R, WIR-1300-R
● ECO-350-R, ECO-350-G, ECO-500-R, ECO-500-G, ECO-750-R
– If one of the following infrared heat plates is connected to the additional
output, the foil sensor P-ISX-FF must be used and activated when start-
ing up the sauna for the first time (see 8.6. Activating/deactivating
the foil sensor on page 31):
● IR-WP-100, IR-WP-175, IR-WP-390, IR-WP-510
● IR-WPHL-100, IR-WPHL-175, IR-WPHL-390, IR-WPHL-510
● Remote start function
The remote start function is deactivated ex-works. When the remote start func-
tion is activated when starting up the unit for the first time, the sauna control
unit may only be used for operating and controlling a sauna heater which
has been certified as satisfying the combustion test described in paragraph
19.101 of EN 60335-2-53. Alternatively, a suitable safety shut-off device can
be installed in or above the heater. Activation of the remote start function
must be carried out by an electrician (see 8.4. Activating/deactivating the
remote start function on page 30).
● Status output
● Automatic heating period limiter
If the operating unit has been running continuously for 6 hours, the sauna
control unit switches off all the consumers for safety reasons. The operating
unit goes into standby mode.
● Post-drying programme
Once combi-mode has finished, the post-drying programme starts automati-
cally to prevent mould or rot from forming in the sauna room. This involves
heating the sauna room to 80 °C with the fan running for 30 minutes.