where the <parameter> should be <group>[_<name>] or <group>[.<name>] If you do not specify the any
parameters, all the parameters on the server will be returned. If you specify only <group>, the parameters of
related group will be returned.
When query parameter values, the current parameter value are returned.
Successful control requests returns paramter pairs as follows.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
<parameter pair>
where <parameter pair> is
<parameter>=<value>\r\n
[<parameter pair>]
<length> is the actual length of content.
Example: request IP address and it's response
Request:
http://192.168.0.123/cgi-bin/admin/getparam.cgi?network_ipaddress
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: 33\r\n
\r\n
network.ipaddress=192.168.0.123\r\n
Set server parameter values
Note: This request require administrator access
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/admin/setparam.cgi? [nosync=<value>&]<parameter>=<value>
[&<parameter>=<value>...][&return=<return page>]
parameter
value
nosync
0, 1
<group>_<name>.
value to assigned
return
<return page>
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: <length>\r\n
\r\n
description
Specifies that there should be no sync (write) of the
corresponding configuration file on flash. If parameter is
omitted, a sync write will occur.
(note: this parameter must be put at begin of parameter list)
Assign <value> to the parameter <group>_<name>..
Redirect to the page <return page> after the parameter is
assigned. The <return page> can be a full URL path or
relative path according the the current path. If you omit this
parameter, it will redirect to an empty page.
(note: The return page can be a general HTML file(.htm,
.html) or a Vivotek server script executable (.vspx) file. It can
not be a CGI command. It can not have any extra
parameters. This parameter must be put at end of parameter
list)