Télécharger Imprimer la page

Publicité

Liens rapides

Franklin Electric Co., Inc.
Oklahoma City, OK
www.lg-outdoor.com
customerservice@lgpc.com
INTRODUCTION
EN
This instruction sheet provides you with the information required
to safely own and operate your Little Giant product. Retain these
instructions for future reference.
The Little Giant product you have purchased is of the highest
quality workmanship and material, and has been engineered
to give you long and reliable service. Little Giant products are
carefully tested, inspected, and packaged to ensure safe delivery
and operation. Please examine your item(s) carefully to ensure
that no damage occurred during shipment. If damage has
occurred, please contact the place of purchase. They will assist
you in replacement or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING
TO
INSTALL,
YOUR LITTLE GIANT PRODUCT. KNOW THE PRODUCT'S
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL
SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!
DESCRIPTION
The F series Flexiflow Pumps provide circulating, oxygenated
water to features such as ponds, fountains, displays, waterfalls,
and filter systems.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRICAL SHOCK. PLEASE OBSERVE
THE FOLLOWING SAFETY GUIDELINES.
WARNING: This pump has not been investigated for use in
swimming pools.
This pump uses a grounding conductor and a grounding-type
attachment plug. To reduce the risk of electrical shock, connect
the pump only to a properly grounded, grounding-type receptacle.
Employ a qualified, licensed electrician to provide electrical power.
Check product label for proper voltage required. Do not connect
to voltage other than that shown.
• F SerieS PUMP
• SÉrie F POMPe
• Serie F BOMBA
CAREFULLY
BEFORE
OPERATE,
OR
SERVICE
Min. 10 in. (25cm)
FIG. 1
To comply with the National Electric Code (NEC) and to reduce
the risk of electric shock, connect the pump only to an outlet
protected by a ground fault circuit interrupter (GFCI).
Check the power cord regularly to ensure that it is in good
condition, with no nicks or cuts.
Do not lift the pump by its power cord.
Do not let the pump freeze during colder temperatures. This can
cause cracking or distortion that will damage the pump. See the
MAINTENANCE section for storage instructions.
Do not operate the pump dry. This will cause the pump to
become extremely hot, causing burns if touched and/or damage
to the pump.
Do not use to pump water hotter than 95°F (35°C).
INSTALLATION AND OPERATION
WARNING: Ensure that the installation conforms with all local and
state electric codes.
NOTE: The pump has thermal overload protection. If it
becomes overheated it will shut off. See the Troubleshooting
section to restart.
In-Water (Submersible) Installation
Refer to Figure 1, Figure 2, and the following steps to configure
the pump for in-water (submersible) use:
1. Locate the electical connection box in a dry area at least 6-1/2
feet (2 meters) from the edge of the water.
2. Place the pump into the water on a flat surface, ensuring that
the pump is completely submersed and that the volute is filled
with water.
CAUTION: If the surface is dirt or sand, place the pump on a
flat object such as a brick or stone to prevent clogging. For
best results, place the pump into a skimmer.
CAUTION: Ensure that the water level does not go below
(25cm) 10 in. when pump is placed directly in pond.
3. Make all necessary intake and discharge connections.
4. Connect the pump to power.
5. Observe that the pump operates properly. Ensure that the
pump will not run dry; without a continuous supply of water
damage will result and void the warranty.
6. If reduced flow is required, restrict the discharge. Never restrict
the intake.
Min. 10 in. (25cm)
FIG. 2
1

Publicité

loading

Sommaire des Matières pour Franklin Electric Little Giant F Serie

  • Page 1 (GFCI). • SÉrie F POMPe Check the power cord regularly to ensure that it is in good Franklin Electric Co., Inc. Oklahoma City, OK • Serie F BOMBA condition, with no nicks or cuts.
  • Page 2 Out-of-Water (Non-Submersible) Installation NOTE: How often the pump requires cleaning depends upon the cleanliness of the water it pumps. When using the pump in hard Refer to Figure 3, Figure 4, and the following steps to configure the water, clean the rotor assembly and the motor housing more often. pump for out-of-water (non-submersible) use: CLEANING (FIGURE 5): 1.
  • Page 3 FIG. 5 rePlAceMent PArtS • rechAnge rePere • rePUeStOS ArtícUlOS (Fig. 5) Item Part No. Repere Description • nomenclature • Descripción Pump Model Nº de Piece Artículo No. de pieza F10-1200, F20-2700, F30-4000, F40-5500, F50- 1, 8, 9 REPLACEMENT SCREEN KIT 166772 5000, F70-7300 REPLACEMENT HOUSING...
  • Page 4 REMARQUE : La pompe comporte un protecteur thermique. En INTRODUCTION cas de surchauffe, elle s’éteint automatiquement. Voir la section Cette feuille d’instructions vous fournit les informations Dépannage pour redémarrer la pompe. nécessaires pour entretenir et faire fonctionner votre produit Installation dans un plan d’eau (submersible) Little Giant.
  • Page 5 REMARQUE : La fréquence de nettoyage de la pompe dépend de NORMAS DE SEGURIDAD la propreté de l’eau pompée. Lorsque le pompe est utilisée avec ADVERTENCIA de l’eau dure, nettoyer l’ensemble du rotor et le boîtier du moteur ADVERTENCIA: PELIGRO DE CHOQUE ELÉCTRICO. OBSERVE plus fréquemment.
  • Page 6 6. Si se requiere un flujo menor, limite la descarga. Nunca restrin- 1. Desconecte la bomba de la corriente eléctrica. ja la entrada de la bomba. 2. Desmonte el filtro de la rejilla de succión (1) (si está en uso) a. instalación fuera del agua (no sumergible) Quite el tornillo (9) en la parte inferior de la rendija b.
  • Page 7 trOUBleShOOting • inFOrMAtiOn SUr lA relÈVe DeS DÉrAngeMentS • inFOrMAciOn De inVeStigAciOn De AVeriAS PrOBleM • FOnctiOnneMent PrOBABle cAUSeS • cAUSeS PrOBABleS cOrrectiVe ActiOn • SOlUtiOnS DÉFecteUX • PrOBleMA • cAUSAS PrOBABleS • SOlUciOn The pump does not run. • La pompe Power cord unplugged.
  • Page 8: Garantie Limitée

    DÉFECTUEUx. of the recommended maximums as set forth in the product instructions. Franklin Electric Company, Inc et ses filiales (ci-après « la Société ») garantit 4. Any product that is operated with any accessory, equipment, component, que les produits accompagnés de cette garantie sont exempts de défauts or part not specifically approved by the Company.
  • Page 9: Garantia Limitada

    DEFECTUOSO. autorisée de produits ne provenant pas de la Société à d'autres produits de Franklin Electric Company, Inc y sus subsidiarias (en adelante “la Compañía”) la Société, et la modification non autorisée des produits de la Société. garantizan que los productos que están acompañados por esta garantía se 6.
  • Page 10 lA cOMPAníA nO SerÁ reSPOnSABle POr lOS DAÑOS AcciDentAleS, 10. Productos en los cuales la bomba fue expuesta a cualquiera de los CONSEQUENTES O ESPECIALES TALES COMO, PERO NO LIMITADOS A: siguientes: arena, grava, cemento, grasa, yeso, barro, brea, hidrocarburos, derivados de los hidrocarburos (aceite, gasolina, solventes, etc.) u otras DAÑOS A O PÉrDiDA De OtrA PrOPieDAD O eQUiPO, PÉrDiDAS sustancias abrasivas o corrosivas.
  • Page 12 For technical assistance, please contact ....1-888-956-0000 Pour l’aide technique, entrez s’il vous plaît en contact ..1-888-956-0000 Para la ayuda técnica, por favor póngase en contacto ..1-888-956-0000 www.lg-outdoor.com customerservice@lgpc.com 998725 - 03/2014 Rev 002...