BEFORE YOU START
BEFORE INSTALLING PUMP, BE SURE TO READ THIS
OWNER'S MANUAL CAREFULLY.
REFER TO PRODUCT DATA PLATE(S) FOR ADDITIONAL
OPERATING INSTRUCTIONS AND SPECIFICATIONS
C A U T I O N
Keep work area clean, well-lit, and uncluttered.
Keep safety labels clean and in good condition.
Wear safety glasses while installing or performing maintenance
on pump.
Adhere to the guidelines of the National Electrical Code (NEC)
or Canadian Electrical Code (CEC), and any other state and
local codes for ALL electrical installations.
Check with the appropriate agencies or contact a licensed electrician.
Adhere to the guidelines of national, state, and local
Hazardous voltage.
plumbing codes when installing this product. Check with the
Can shock, burn, or
appropriate agencies or water system professional for
cause death.
additional information.
Ground pump before
Most water system problems result from improper installation.
connecting to power
It is suggested that you read this manual carefully before
supply. Disconnect
installing your pump.
power before working
The "TROUBLESHOOTING SECTION" will assist you in
on pump, motor
locating and eliminating the cause of any trouble you may
or tank.
encounter after installation. Check and make available all the
tools you will need to install your pump. Required tooling may
include wrenches, pipe sealant, pipe fittings and nipples,
screwdriver, etc. Be sure to have available proper and
adequate wiring material to complete the installation correctly.
106810101
Rev. 5
10.14
INLINE PRESSURE
BOOSTING SYSTEM
OWNER'S MANUAL
IMPORTANT INFORMATION FOR INSTALLERS OF
This equipment is intended for installation by technically
qualified personnel. Failure to install it in compliance with
national and local electrical codes, and within Franklin Electric
recommendations, may result in electrical shock or fire hazard,
unsatisfactory performance, and equipment failure. Franklin
Electric installation information is available from pump
manufacturers and distributors, and directly from Franklin
Electric. Call Franklin Electric toll free at 800-348-2420
for information.
W A R N I N G
Serious or fatal electrical shock may result from failure to
connect the inline system, metal plumbing, and all other metal
near the inline system or cable, to the power supply ground
terminal using wire no smaller than the power cord wires. To
reduce risk of electrical shock, disconnect power before
working on or around the water system. Do not use inline
system in swimming areas.
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this
on your pump or in this manual, look for one of the following
signal words and be alert to the potential for personal injury:
D A N G E R
personal injury, death or major property damage if ignored.
W A R N I N G
serious personal injury, death or major property damage if ignored.
C A U T I O N
cause minor personal injury or major property damage if ignored.
Hazardous voltage.
WA R N I N G
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
N O T I C E
important but not related to hazards. Carefully read and follow
all safety instructions in this manual and on pump.
W A R N I N G
pump against closed discharge. Release all system pressure
before working on any component.
C A U T I O N
before starting or pump will be damaged.
ATTENTION!
THIS EQUIPMENT!
warns about hazards that will cause serious
warns about hazards that can cause
warns about hazards that will or can
WA R N I N G
indicates special instructions which are
HAZARDOUS PRESSURE: Do not run
Do not run pump dry. Fill pump with water
symbol
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Franklin Electric 92061503

  • Page 1 This equipment is intended for installation by technically qualified personnel. Failure to install it in compliance with national and local electrical codes, and within Franklin Electric recommendations, may result in electrical shock or fire hazard, unsatisfactory performance, and equipment failure. Franklin...
  • Page 2: Electrical Safety

    GENERAL SAFETY N O T I C E The Inline Pressure Boosting System is The Franklin Electric Inline Pressure Boosting System has a type designed for indoor use only. 2 enclosure rated for indoor use only. PLUMBING, PIPING, and HOSES INLINE SYSTEM KEY FEATURES In general, keep the suction and discharge lines as large as possible.
  • Page 3: Pressure Tank

    INSTALLATION PROCEDURE – PLUMBING (Appendix 2) to determine the amount of head lost for a given application. Disconnect electrical power at the main breaker. PRESSURE TANK Drain the system (if applicable). The Inline Pressure Boosting System needs a small pressure Mount the Inline Pressure Boosting System in the desired tank placed on the pump outlet to reduce cycling.
  • Page 4: Lubrication

    Disconnect electrical power at the main breaker. Once the pump is operating, fully open the discharge valve and a system outlet, letting the pump operate until the water is Verify that the dedicated branch circuit for the Inline running clear. No further priming should be needed unless the Pressure Boosting System is equipped with a 15 amp pump is drained or there is a leak in the suction plumbing.
  • Page 5 Reassembly is reverse of disassembly. indicating calibration is complete. Release the button and the red LED should come on solid, indicating calibration CIRCUIT BOARD REPLACEMENT was successful. It is possible that the main circuit board of the Inline Pressure Open tap to begin water flow and confirm unit is Boosting System could become damaged.
  • Page 6 APPENDIX 1 – INLINE PRESSURE BOOSTING SYSTEM PERFORMANCE CURVE...
  • Page 7 APPENDIX 2 – FRICTION LOSS TABLES Note: Chart shows friction loss per 100’ of pipe. To convert to friction loss per foot, move decimal point two places to the left. Schedule 40 pipe 0.824 in. i.d. / Type L Copper tube 0.785 in. i.d. Schedule 40 pipe 1.38 in.
  • Page 8 The buyer must return the product to an authorized Franklin Electric Distribution outlet for warranty consideration. Returns to the place of purchase will only be considered for warranty coverage if the place of purchase is an authorized Franklin Electric Distributor at the time the claim is made.
  • Page 9: Système De Surpression En Ligne

    Les directives d’installation de Franklin Electric sont offertes par les fabricants et les distributeurs de la pompe de même que par Franklin Electric directement. Communiquez avec Franklin Electric en composant le numéro sans frais 800-348-2420 pour en savoir davantage.
  • Page 10: Électricité Et Sécurité Attention

    REMARQUE Le système de surpression en ligne est conçu pour un usage intérieur uniquement. Le système de surpression en ligne Franklin Electric comprend un boîtier de type 2 conçu pour un usage intérieur uniquement. PLOMBERIE, TUYAUTERIE ET TUYAUX PRINCIPALES CARACTÉRISTIQUES DU En général, gardez les lignes d’aspiration et de refoulement aussi...
  • Page 11: Réservoir Pressurisé

    Consultez les tableaux de rendement du système de surpression Un sectionneur à fusibles ou un disjoncteur devrait être en ligne ci-joints (annexe 1), ainsi que les tableaux de perte situé sur la pompe ou à proximité, conformément aux codes de de charge (annexe 2) afin de déterminer la perte de charge l’électricité...
  • Page 12: Démarrage

    AVERTISSEMENT d’évacuation d’air. Préparez-vous à ce qu’un mélange d’air et Le système de surpression en ligne peut d’eau soit refoulé par la soupape. générer une pression très élevée dans certaines situations. Veillez Une fois tout l’air évacué, fermez la soupape. Le refoulement à...
  • Page 13: Dépannage

    Éteignez le système avant de retirer le couvercle. Il se Retirez les deux vis qui maintiennent le plateau de la carte de peut que le système soit sous pression. Ainsi, vous circuit en place. devriez vidanger le boîtier de la pompe avant d’effectuer la Débranchez les deux interrupteurs à...
  • Page 14: Annexe 1 - Courbe De Rendement Du Système De Surpression En Ligne

    ANNEXE 1 – COURBE DE RENDEMENT DU SYSTÈME DE SURPRESSION EN LIGNE (gallons/ minute) (litres/minute)
  • Page 15: Annexe 2 - Tableaux De Perte De Charge

    ANNEXE 2 – TABLEAUX DE PERTE DE CHARGE Remarque : Le tableau montre la perte de charge par 100 pi (30,48 m) de tuyau. Pour convertir la valeur en perte de charge par pied, déplacez le signe décimal de deux chiffres vers la gauche. Tuyau série 40, diam.
  • Page 16: Garantie Limitée

    L’acheteur doit retourner le produit à un point de distribution Franklin Electric autorisé pour examen. Si le retour est effectué au point d’achat, la couverture de la garantie ne sera prise en considération que si le lieu de vente en question est un distributeur Franklin Electric autorisé au moment de la réclamation.
  • Page 17: Antes De Comenzar

    La información necesaria o adicional para la instalación se encuentra disponible con el distribuidor o en su defecto puede solicitarla directamente con Franklin Electric Para obtener más información, llame a la línea gratuita de Franklin Electric al 800-348-2420. ADVERTENCIA Asegúrese de no conectar el Sistema Inline y sus componentes...
  • Page 18: Seguridad General

    Los niños deben supervisarse para asegurar que ellos SEGURIDAD GENERAL no empleen los aparatos como juguete. El Sistema de presurización Inline Franklin Electric tiene un A V I S O Cuando se monte horizontalmente, gabinete de tipo 2 clasificado para uso solamente en interiores.
  • Page 19: Tubería De Succión

    bombeo. No hay un requerimiento de flujo de entrada, que no sea Desconecte la alimentación en el panel eléctrico antes de que el sistema necesita tener un suministro de agua constante hacer cualquier conexión eléctrica. El voltaje de suministro debe para tener la unidad completamente llena de agua en todo ser +/- 10% del voltaje indicado en la placa del Sistema de momento.
  • Page 20 Instale el tanque de presión después de la bomba. El tanque Inserte un tapón de 1/8 pulg NPT en el orificio de salida de debe estar ubicado en un rango de 5 pies de la descarga de aire en la cabeza de control. la bomba.
  • Page 21: Solución De Problemas

    LIMPIEZA DEL INTERRUPTOR DE FLUJO Quite los 6 tornillos que aseguran la tapa. En algunos casos el interruptor de flujo se puede obstruir o Quite la tapa cuidando que no se dañe la conexión de la bloquear. En esos casos el interruptor se puede limpiar con los interfaz de usuario.
  • Page 22 APÉNDICE 1 - CURVA DE RENDIMIENTO DEL SISTEMA DE PRESURIZACIÓN INLINE pies...
  • Page 23 APÉNDICE 2 - TABLAS DE PÉRDIDAS POR FRICCIÓN Nota: La tabla muestra las pérdidas por fricción por 100 pies de tubería. Para convertir a pérdidas por fricción por pie, mueva el punto decimal dos lugares a la izquierda. Tubo cédula 40 con diámetro interno de 0.824 pulg. / Tubo de cobre tipo L con diámetro Tubo cédula 40 con diámetro interno de 1.38 pulg.
  • Page 24: Garantía Limitada

    El comprador deberá enviar el producto a un distribuidor autorizado de Franklin Electric para hacer uso de la garantía. Las devoluciones al lugar de compra solo se considerarán para la cobertura de la garantía si el lugar de compra es un Distribuidor de Franklin Electric al momento en el que se haga la reclamación.

Table des Matières