Chapter 8: Assembly For Transport And Access Through Doors; Chapter 9: Verification, Upkeep And Maintenance - NF GENERIS 750 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
Chapter 8:
The GENERIS 750 and 950 mobile scaffolding fit through a door with a minimum width of 0,86 m and a
minimum height clearance of 2.15m.
The scaffolding can also be used to transport equipment and small tools.
To extend the life of your scaffolding, it is recommended to store it away from bad weather.
Chapter 9:
CHECKS:
Inspect parts before each assembly, particularly:
- castor wheels tyres and brakes,
- safety devices (split pin, adaptor, etc.),
- working platform hooks and fasteners.
- the plywood on the working platforms.
- the stabiliser mounting brackets.
- the welds on the ladder rungs.
All parts with the following defects:
- permanent deformation.
- perforations.
- score marks (as a result of grinding, for example...)
- severe oxidation
- weld failure starting out,
... should be discarded!
If in doubt, change the part.