27. Mount the 2 temporary guard rails on rung no. 29 by following §3-1-7.
28. Mount the two 1.50m extensions (without the 0.60m extension) by following § 3-1-6.
29. Remove the 2 temporary guard rails, and then mount them definitively on rung no. 33 by
following § 3-1-7.
30. Mount the 11
31. Mount the 4
32. Mount the two 1.50m + 0.60m extensions by following §3-1-6.
33. Mount the 10
34. Mount the 15
35. Mount the 5
36. Mount the access cradle by following §3-1-12.
37. Check the position of components by following §2-5-5.
38. For heights below the 11.50m platform, lower the guard rails and platforms according to
the required height. If necessary, remove the 1
rails.
39. Note that the distance between rungs = 300mm.
40. To comply with EN1004-1, the minimum height between platforms must always be 2.10m,
and the height of the first platform must be <3.40m.
106-A000035745 - ind.0 – 11/2021
th
th
th
th
, 12
, 13
and 14
th
permanent platform on rung no. 30 by following §3-1-9.
th
th
and 12
guard rails on rung no. 40.
th
th
and 16
cross braces by following §3-1-10.
th
and last platform on rung no. 37 by following §3-1-9.
cross braces by following §3-1-10.
st
platform along with the 1
st
nd
and 2
guard
87