Chapter 2: Scaffolding Technical Specifications; Marking; Nf Marking - NF GENERIS 750 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
Chapter 2:

2-1. Marking

NF EN 1004 3 8M/12M XXXD H2
reference standard

2-2. NF Marking

Marking of G750 2.8m to 11.5m platform:
Marking of G950 2.8m to 11.5m platform:
1:
NF logo in compliance with the graphic charter in force
2: Licence holder's number
3: Identification of the producing factory (C = COMABI)
4: Reference of the scaffolding model(s) (G7 = G750 / G9 = G950)
5: Standard reference: Mobile scaffolding pursuant to EN1004-1
6: Reference to the year of manufacture
7: Manufacturing batch number
106-A000035745 - ind.0 – 11/2021
Scaffolding technical specifications
load
category
Maximum height for indoor /
exterior use
NF 04 C G7 R XX XX
1
2 3 4
5 6
NF 04 C G9 R XX XX
1
2 3 4
5 6
access by stairs: no
access by steps: no
access by inclined ladder: no
access by vertical ladder: yes
Height between platforms
H1: 1.85 m
H2: 1.9 m
7
7
55