Les langues disponibles

5.3

Environment

5.3.1 Temperature range

Environmental conditions
Operating temperature range
Storage temperature range

5.3.2 Mechanical environment

Environmental conditions
Safety class to EN 60529
Safety class to DIN 40050-9
* Modification 100
5.4

Input data

Input parameters
Measuring length
Distance between start of measuring
zone and flange housing
Distance between end of rod and end
of measuring zone
5.5

Output data

Output data
Output signal
Repeatability
Hysteresis
Linearity discrepancy
Accuracy class
Ohmic resistance to GND
Reaction time of the output signal

6 Operating elements

The linear position transducer does not have any operating controls. User intervention
is therefore neither possible nor necessary.

7 Commissioning

The user manual instructions must be followed. The geometry and cleanliness of the
installation space, the sound condition of the sealing surfaces and sealing elements,
and the electrical connection are particularly crucial.

8 Interval between repeat testing

The operating life of the position transducer is defined as 20 years. The reliability of
the electrical, electronic and mechanical components is such that no repeat testing is
required during the unit's operating life.
Value
- 40 ... 85 °C
- 40 ... 100 °C
Value
IP 66 * / 67
IP 69 K *
Value
200 ... 2500 mm
≥ 30 mm
≥ 63 mm
Value
4 ... 20 mA
+/- 0.1 % FS
+/- 0.1 % FS
+/- 0.1 % FS
+/- 0.5 % FS
200 ... 500 Ω
≤ 30 ms (10 ... 90 %)
7