General Transmitter Layout; Appliance Operation; Hand Held Remote Operations; Temperature Display - Napoleon IR3GN Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2

GENERAL TRANSMITTER LAYOUT

TRANSMISSION
CHILD SAFETY
LOW BATTERY
ALARM
6
TEMPERATURE SET POINT/ LEVEL/ STATUS
FLAME
6.3

APPLIANCE OPERATION

A.
Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-). (Only required
as back up to household electricity).
B.
Place the 3 position slider switch of the receiver in the "Remote" position.
C.
Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole
marked "PRG" on the receiver front cover. The receiver will "beep" three (3) times to indicate that it is
ready to synchronize with the transmitter.
D.
Install the 3 AAA batteries in the transmitter battery bay, located on the base of the transmitter.
With the batteries already installed in the transmitter, push the "ON" button. The receiver will "beep"
four times to indicate the transmitter's command is accepted and set to the particular code of that
transmitter. The system is now initialized.
6.4

HAND HELD REMOTE OPERATIONS

A.
Press the ON/OFF key on the transmitter. The transmitter
display will show all active icons on the screen. A single
"beep" from the receiver will confi rm reception of the
command.
6.5

TEMPERATURE DISPLAY

A.
With the system in the "OFF" position, press the
Temperature Key and the Mode Key at the same
time to change from degrees F to C.
B.
Look at the LCD screen on the Transmitter to
verify that a C or F is visible to the right of the
Room Temperature display.
LOCK OUT
ROOM
TEMPERATURE
FAN
AUX. OUTPUT
35.2A
BLUE LCD DISPLAY
ON/OFF KEY
TEMPERATURE KEY
UP/DOWN
ARROW KEY
MODE KEY
35.4A
°F
73
35.5A
W415-1355 / A / 11.16.16
17
EN
°C
23

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ir3gp

Table des Matières