- Do not leave devices out in the rain.
- Check the plugs and cables regularly and
have them replaced by an expert if dama-
ged.
- Do not lift or carry the devices by their
handles using a crane hook or lifting
gear.
- The device may only be used by persons
who have been trained in its use and who
are authorised to do so.
- If noxious dusts have been extracted, the
vacuum cleaner and all accessories must
be completely cleaned (inside and outside)
by suction and wiping, before removal
from the contaminated area.
Parts that cannot be completely cleaned
are to be packed for transport in a plastic
bag with an airtight seal.
- For safety reasons, only operate the ma-
chine using a totally earthed socket.
3
Appliance preparation and initial
operation
Stick the enclosed sticker in your national
language on the text area of the warning
plate (5.7).
3.1
Electrical connection
The operating voltage shown on the
rating plate must correspond to the
voltage of the mains power supply.
Make sure that the vacuum cleaner
is switched off when you plug the-
power cable in.
3.2
On/off switch (1.1)
In position 0 the vacuum cleaner is switched
off and the appliance plug socket (1.3) is
dead.
Two modes of operation are possible:
a)
Switch position „MAN"
The appliance plug socket is live.
Before turning the switch to the
„MAN" position, ensure that the tool
connec-ted to the appliance plug
socket is switched off.
The cleaner motor starts immediately.
b)
Switch position „Auto"
The appliance plug socket is live.
Before turning the switch to the
„Auto" position, ensure that the tool
connected to the appliance plug so-
cket is switched off.
The cleaner motor starts only when the tool
connected to the appliance plug socket is
switched on.
3.3
Suction force regulator (1.2)
The suction force regulator can be used to
vary the suction capacity. This permits a
precise adaptation to different substances
to be picked up.
3.4
Connecting an electric tool
Observe the maximum connected load on
the appliance plug socket (see "Technical
Data")! Connect the electric tool to the ap-
pliance plug socket (1.3).
Make sure that the electric tool is
switched off when plugging it in and
unplugging it.
4
Operation
4.1
Changing the fi lter
During the following procedure, take care
not to raise dust more than is unavoidab-
le.
Wear a P2 breathing protection mask
with health-hazardous dusts!
a)
Changing the fi lter bag
Order No.:
CTL MINI 456772, CTL MIDI 494105
- Open locking clips (1.4), remove top sec-
tion (1.5),
- Change fi lter bag (2.1)–see print on fi lter
bag,
- Replace top section, close locking clips.
Note: A replacement fi lter bag can be
stored in the storage compartment (5.4).
b)
Changing the fi lter element
Order No.: 456790
Do not operate machine without a
fi lter element. This may damage the
motor.
- Open locking clips (1.4), remove top sec-
tion (1.5),
- Fold over handle (3.2) and remove holder
(3.3),
- Remove used fi lter element (3.4) and re-
place with a new one,
- Replace holder and fold over handle until
it latches into place,
- Replace top section, close locking clips.