Electrical Data - Zoeller X6161 Mode D'emploi

Pour environnement dangereux
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model
HP
RPM
NX6161
1/2
3450
EX6161
1/2
3450
IX6161
1/2
3450
JX6161
1/2
3450
FX6161
1/2
3450
GX6161
1/2
3450
BAX6161
1/2
1725
NX6163
1/2
3450
EX6163
1/2
3450
IX6163
1/2
3450
JX6163
1/2
3450
FX6163
1/2
3450
GX6163
1/2
3450
BAX6163
1/2
1725
EX6165
1
3450
IX6165
1
3450
JX6165
1
3450
FX6165
1
3450
GX6165
1
3450
BAX6165
1
3450
EX6185
1
3450
IX6185
1
3450
JX6185
1
3450
FX6185
1
3450
GX6185
1
3450
BAX6185
1
3450
EX6186
1-1/2
3450
IX6186
1-1/2
3450
JX6186
1-1/2
3450
FX6186
1-1/2
3450
GX6186
1-1/2
3450
EX6188
1-1/2
3450
IX6188
1-1/2
3450
JX6188
1-1/2
3450
FX6188
1-1/2
3450
GX6188
1-1/2
3450
BAX6188
1-1/2
3450
EX6189
2
3450
IX6189
2
3450
JX6189
2
3450
FX6189
2
3450
GX6189
2
3450
BAX6189
2
3450
NX6282
1/2
1725
EX6282
1/2
1725
IX6282
1/2
1725
JX6282
1/2
1725
FX6282
1/2
1725
GX6282
1/2
1725
BAX6282
1/2
1725
EX6284
1
1725
IX6284
1
1725
JX6284
1
1725
FX6284
1
1725
GX6284
1
1725
BAX6284
1
1725
NX6292
1/2
3450
EX6292
1/2
3450
IX6292
1/2
3450
JX6292
1/2
3450
FX6292
1/2
3450
GX6292
1/2
3450
BAX6292
1/2
3450
EX6293
1
3450
IX6293
1
3450
JX6293
1
3450
FX6293
1
3450
GX6293
1
3450
BAX6293
1
3450
EX6294
1-1/2
3450
IX6294
1-1/2
3450
* Line to line reading will only reflect the run winding resistance.
Start winding resistance can only be measured after removing the cover.

ELECTRICAL DATA

Voltage
Phase
Hertz
115
1
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
115
1
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
115
1
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
115
1
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
200
3
60
230
3
60
460
3
60
575
3
60
230
1
60
200
1
60
CONTINUED ON NEXT PAGE
© Copyright 2017 Zoeller
Amps
Full Load
In Air
Shut Off
15.5
7.7
7.5
3.6
8.8
6.3
6.4
3.1
5.2
2.7
2.9
1.4
2.4
1.3
15.0
8.4
7.5
4.0
8.5
4.3
6.0
3.4
4.8
3.0
2.9
1.5
2.4
1.5
10.2
5.5
12.6
6.1
7.5
4.8
7.4
3.8
3.7
2.1
3.0
1.7
9.8
5.0
11.5
5.1
7.5
3.6
7.4
3.8
3.7
1.9
3.3
1.6
13.7
9.3
17.2
11.8
10.3
6.0
9.2
5.5
4.6
2.8
14.0
7.4
16.8
9.8
10.3
4.7
8.9
4.1
4.6
2.0
3.5
1.6
17.1
9.4
20.5
11.5
13.2
6.0
11.2
5.1
6.0
2.8
5.8
2.1
10.3
7.3
5.0
4.0
6.1
4.5
3.6
2.5
3.0
2.3
1.7
1.1
1.4
1.1
8.9
6.7
9.3
6.4
5.5
4.0
5.0
4.0
2.6
1.9
2.2
1.7
15.0
10.6
7.5
4.7
8.8
7.4
6.4
4.0
5.2
3.5
2.9
1.7
2.4
1.7
10.2
6.6
12.0
7.5
8.2
5.2
7.6
5.2
4.0
2.6
3.3
2.1
13.7
9.7
17.8
11.6
Co. All rights reserved.
®
3
KVA
Resistance
Locked Rotor
Code
Line-to-Line
52.2
N
15.1
H
4.74/3.88*
19.8
J
3.59/2.94*
23.6
S
6.25/5.12
24.0
T
12.0
T
22.8/18.5
11.3
U
38.0/33.0
52.2
N
15.1
H
4.74/3.88*
19.8
J
3.59/2.94*
23.6
S
6.25/5.12
24.0
T
12.0
T
22.8/18.5
11.3
U
38.0/33.0
20.1
E
3.06/2.51*
26.8
F
2.11/1.72*
31.1
M
3.74/3.06
29.8
N
14.9
N
22.6/18.2
10.0
L
38.8/34.5
20.1
E
3.06/2.51*
26.8
F
2.11/1.72*
31.1
M
3.74/3.06
29.8
N
14.9
N
22.6/18.2
10.0
L
38.8/34.5
45.7
H
1.29/1.05*
54.5
J
45.2
M
2.62/2.14
39.4
M
19.7
M
45.7
H
1.29/1.05*
54.5
J
45.2
M
2.62/2.14
39.4
M
19.7
M
15.9
M
20.6/18.3
45.7
F
1.29/1.05*
54.5
F
45.2
J
2.62/2.14
39.4
J
19.7
J
15.9
J
20.6/18.3
30.2
H
1.46/1.20*
15.1
H
5.84/4.80*
17.7
H
4.65/4.05*
12.8
K
8.13/6.62
12.2
L
6.1
L
38.4/31.5
5.11
M
63.6/55.3
24.9
G
2.62/2.14*
26.8
F
2.01/1.82*
26.3
L
2.99/2.70
22.2
K
11.1
K
19.2/17.4
12.1
N
20.4/17.7
52.2
N
15.1
H
4.74/3.88*
19.8
J
3.55/2.94*
23.6
S
6.25/5.12
24.0
T
12.0
T
22.8/18.5
11.3
U
38.0/33.0
20.1
E
3.06/2.51*
26.8
F
2.11/1.72*
31.1
M
3.74/3.06
29.8
N
14.9
N
22.6/18.2
10.0
L
38.8/34.5
45.7
H
1.29/1.05*
54.5
J
Winding
.53/.46*
5.7/4.6
.53/.46*
5.7/4.6
5.7/4.5
5.7/4.5
.86/.71*
3.52/2.8
13.9/11.3
.86/.71*
3.52/2.8
13.9/11.3
.86/.71*
3.5/2.8
13.9/11.3
9.6/7.9
4.8/4.4
.53/.46*
5.7/4.6
5.7/4.5
.86/.71*

Publicité

Table des Matières
loading

Table des Matières