Notice to installing contractor: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test/
oil fill plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
1. Make certain that the receptacle is within the reach of the pump's power
supply cord. DO NOT USE AN EXTENSION CORD. Extension cords that
are too long or too light do not deliver sufficient voltage to the pump motor
and could present a safety hazard if the insulation were to become damaged
or the connection end were to fall into a wet or damp area.
2. Check to be sure your power source is capable of handling the voltage
requirements of the motor, as indicated on the pump name plate.
3. Make sure the pump electrical supply circuit is equipped with fuses or
circuit breakers of proper capacity. A separate branch circuit is recommended,
sized according to the "National Electrical Code" for the current shown on the
pump nameplate.
4. Testing for ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly connected
to your outlet. If they are not, call a qualified licensed electrician.
5. For Added Safety. Pumping and other equipment with a 3-prong grounded
plug must be connected to a 3-prong grounded receptacle. For added safety
the receptacle may be protected with a ground-fault circuit interrupter. When
a pump needs to be connected in a watertight junction box, the plug can be
removed and spliced to the supply cable with proper grounding. For added
safety this circuit may be protected by a ground-fault circuit interrupter. The
complete installation must comply with the National Electrical Code and all
applicable local codes and ordinances.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied
with a 3-prong grounded plug to help protect you against the possibility of
electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE
GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong
grounded receptacle. If the installation does not have such a receptacle, it
must be changed to the proper type, wired and grounded in accordance with the
National Electrical Code and all applicable local codes and ordinances. Three
phase pumps require motor starting devices with motor overload protection.
See FM0486 for duplex installations.
7. Risk of electric shock. Do not remove power supply cord and strain relief or
connect conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should be performed
by a qualified licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electric shock. These pumps have not been investigated for use in
swimming pool and marine areas.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
INSTALLATION INSTRUCTIONS
MODELS 63 AND 95
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2016 Zoeller
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL. When you see this
symbol on the pump or in the manual, look for one of the
following signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that can cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to and external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO CAUTIONS AND WARRANTY ON PAGE 2.
Co. All rights reserved.
®
1
FM2895
Supersedes
Visit our web site:
zoellerpumps.com
DATE INSTALLED:
MODEL NUMBER:
NOTICE: VENT HOLE FOR
CHECK VALVE
SEE #1 IN CAUTION SECTION
ON PAGE 2 AND #4 ON PAGE 4
0916
0816