Technical Data - Kospel EPS2 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operation
The heater is produced in 2 versions: EPS2-3,5 and EPS2 4,4 that is without power
changing knob, EPS2-5,5 that is equipped with a power changing knob which is
placed on the front cover. There are 2 possible positions that the knob can be situated.
In „(" position the appliance uses lower power than in a position „))"– in that case
the maximum power is used. The knob is easily turned in both directions. There is
a heating „on" indicator near the knob.
Faults
In case the appliance does not heat water, check for possible reasons:
-
a failure of the mains supplies (e.g. fuses),
-
insufficient flow rate through the heater (e.g. dirty filter, incorrect setting of the
hot water tap).
The guarantee does not cover the above repairs.
If there is a fault in the appliance (the heater does not work and all the above reasons
do not occur), contact the nearest authorised service point or the seller.

Technical data

EPS2 water heater
Rated power
Rated voltage
Rated current
Min. supply water pressure
Operating point
Efficiency (at ∆t = 30°C)
Overall dimension (length without a tap x width x depth)
Weight (with a tap)
Conductor to connect with electrical installation (1.2m long)
Min. water resistivity at 15°C
Min. connecting wires section
The maximum allowed network impedance
Water supply pipe section
Safety class
14
3,5
4,4
kW
3,5
4,4
230V~
A
15,2
19,1
MPa
0,12
l/min
1,1
1,7
l/min
1,7
2,1
mm
195 x 135 x 69
kg
~1,4
with assembly terminals
Ωcm
1100
mm
3 x 1,5
2
0,34
G1/2"
IP 25
5,5R
5,5/4,4
23,9/19,1
2,0
2,6/2,1
3 x 2,5
0,31

Publicité