Robotic Lawnmower
Docking station
Input voltage
Power consumption charging/perimeter wire switched on
Charging current (up to)
Allowable charging temperature range
Weight according to EPTA-Procedure 01:2014
Protection type
Power supply unit
Switzerland
United Kingdom
Rest of Europe
Input voltage (AC)
Protection class
Frequency
Output voltage (DC)
Protection type
Weight
A) Depends on cutting height, grass conditions and moisture
B) Internal battery temperature
The specifications apply to a rated voltage [U] of 230 V . These specifications may vary at different voltages and in country-specific models .
Noise/Vibration Information
Noise emission values determined according to
EN 50636-2-107 .
Typically the A-weighted noise levels of the product are:
Sound power level 61 dB(A) . Uncertainty K = 2 dB .
Explanation of Figures
Action
Accessories
Delivery scope/unpacking the
mower
Laying out perimeter wire
Extending perimeter wire
Laying perimeter wire around new
inner object
Lifting up and carrying the mower
Setting the height of cut
Place & Mow
Adding a further lawn area
– with additional docking station
(right)
– without additional docking station
(top left)
Cleaning
Maintenance
B)
Installation
Remove straw, stones, loose pieces of wood, wire, live
mains cables and other foreign objects from the cutting
area . Make sure that the cutting area is even and has no
ditches, grooves and steep slopes above 15°/27 % that
Figure Page
are clear obstructions for the mower .
A
22
The docking station must be positioned on the wire at an
B
23
outer edge of the cutting area . It may not be positioned
on the side of a tool or garden shed standing as an island
C
23
within the lawn to be mowed .
D
24
It is recommended that you mow your lawn once with a
E
24
conventional lawnmower before installing and before the
first mowing of the new season and whenever the grass
clippings would be longer than 5 mm .
F
25
The mower's cutting system is designed to cut small
G
25
lengths of grass (30–50 mm) . The clippings can remain as
H
26
mulch to fertilize the lawn . The height of cut for mower
I
26
can be adjusted to 30, 40 and 50 mm .
For the first few weeks of usage, set the height of
cut to 50 mm to prevent the perimeter wire being cut .
Afterwards, the wire will be covered by the lawn .
Additional perimeter wire can be added using a wire
connector (see figures D–E) .
J
27
The perimeter wire can be extended up to a maximum
K
27
length of 250 m .
Unit
VDC
W
A
°C
kg
V
Hz
V
kg
Check if the perimeter wire is fully pegged
to the ground avoiding any slack lengths of
wire . Any loose wire can be a trip hazard .
English | 9
Miimo HRM40
24
55/2 .6
2 .3
5–45
1 .65
IPX4
80016-Y0E-003X
80015-Y0E-003X
80014-Y0E-003X
220–240
/ II
50–60
24
IPX7
0 .8