Troubleshooting - Honda MIIMO HRM40 Instructions Originales

Masquer les pouces Voir aussi pour MIIMO HRM40:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
Main Menu
Sub-menu 1
Advanced
Tools

Troubleshooting

Problem
The LED on the
docking station
flashes
Excessive vibrations/
noise
Mower not docking
reliably
Sub-menu 2
Wire ID
Sensor setting/
Lawn condition
Remap
Factory Reset
Garden overview
Delete garden
Name mower
Level check
Wire signal
Possible Cause
The perimeter wire is
interrupted, too long or too
short . Wire not connected
and mower not in the docking
station .
Blade bolt loose
Cutting blade damaged/bent
Perimeter wire not properly
layed out around docking
station
Perimeter wire close to a
source of interference
Explanation
Change the perimeter wire ID when possible
interferences are nearby .
Select between Low (uneven ground), Normal and High
(slippery ground) . Mower bump sensor will become more
or less sensitive depending on lawn condition selected .
Deletes the current map of the garden .
Reset the mower to factory settings will delete all
personal settings (not PIN) .
After a factory reset, the mower will need to remap the
gardens .
Displays the number of mapped gardens, their size, their
wire ID and the date of the last time the garden was cut .
Delete one specific garden map or select to delete all
maps at once .
Change the name shown in the display . Only letters of
the Latin alphabet are possible . The number of letters is
limited . This function is not available in every language .
In some languages (e .g . Czech or Polish) a name change
doesn't have effect on display due to specific grammar
requests .
Information about the ground angle of the mower . If the
mower is in the docking station and the dot on the display
is not within the indicated circle, the docking station must
be repositioned in a new, more level location .
Detects the wire signal received from the perimeter wire,
indicating its strength (for Service Agent) .
The mower will not receive any wire signal while in the
docking station .
Corrective Action
Check that the perimeter wire is not interrupted and is
between 20 and 250 meters in length . Then switch power
supply off and then on again .
Follow instructions in Installation Guide on installing the
mower .
Tighten blade bolt to torque of 2 .5 Nm .
Replace cutting blade (see figure K) .
Follow instructions in Installation Guide on layout of
perimeter wire .
Remove any excess (e .g . coiled up) perimeter wire
around the docking station .
Change perimeter wire ID in the menu .
English | 13