Accessory List; Precautions For Handling And Operation - NSK FX 205 M4 Mode D'emploi

Masquer les pouces Voir aussi pour FX 205 M4:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39

Accessory List

No.
Part Name
1
FX Wrench
2
Cap Wrench
3
FX Spray Nozzle
4
Spray Nozzle
5
E-Type Spray Nozzle
6
Turbine Oil

Precautions for handling and operation

• P lease read these precautions carefully and use only as intended or instructed.
• S afety instructions are intended to avoid potential hazards that could result in personal injury or damage
to the device. Safety instructions are classified as follows in accordance with the seriousness of the risk.
Class
Hazard that could result in serious injury or damage to the device if the safety
WARNING
instructions are not correctly followed.
Hazard that could result in light or moderate injury or damage to the device if the
C A U T I O N
safety instructions are not correctly followed.
General product specification information highlighted to avoid product malfunction
N O T I C E
and performance reduction.
2
Quantity
Remarks
1
FX205 M4 Set
FX205 B2 Set
FX205 M4/FX22 Set
FX205 B2/FX22 Set
FX205 M4/FX25 Set
FX205 B2/FX25 Set
FX205m M4 Set
FX205m B2 Set
1
FX205 M4/FX22 Set
FX205 B2/FX22 Set
1
FX205 M4 Set
FX205 B2 Set
FX205 M4/FX25 Set
FX205 B2/FX25 Set
FX205m M4 Set
FX205m B2 Set
1
FX205 M4/FX22 Set
FX205 B2/FX22 Set
1
-
1
-
Degree of Risk
Air Motor (FX205 M4/FX205m M4/FX205 B2/FX205m B2)
CAUTION
• R ead this Operation Manual before use to fully understand the product functions and file for future
reference.
• W hen operating the product always consider the safety of the patient.
• U sers are responsible for the operational control, maintenance and continual inspection of this
product.
• D o not disassemble or alter the motor except as recommended by NSK in this Operation Manual.
• D o not allow any impact on to the product. Do not drop the product.
• O perators and all others in the area must wear eye protection and a mask when operating this motor.
• S hould the motor function abnormally during use, stop using the motor immediately and contact your
Authorized NSK Dealer.
• D o not use the following fluids to wipe, immerse or clean the product; strong/super acid water,
strong acid/alkaline chemicals, chlorine-containing solutions, solvents such as benzine or thinner.
• T he motor is delivered in a non-sterile condition and must be autoclaved prior to use.
• P erform regular function and maintenance checks. (Refer to "7. Periodical Maintenance Checks")
• I f the motor has not been used for a long period, rotate the motor and check for noise, vibration and
overheating before use.
• T o avoid clinical downtime it is recommended that a spare be kept on hand in case of a breakdown
during treatment.
• U .S. Federal law restricts this device to sale by or on the order of a licensed physician.

Publicité

Table des Matières
loading

Table des Matières