D E S I G N E R Safety Information O K E A N I TO WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. WARNING We have provided many important safety messages in this manual for your appliance.
Page 5
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and...
D E S I G N E R Safety Information O K E A N I TO WA L L READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
D E S I G N E R Installation Instructions O K E A N I TO WA L L Ducting Calculation Sheet Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3- 1/ 4” x 10” 1 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round duct work must be used to maintain maximum air flow efficiency with the 290/600 CFM internal blower. A minimum of 8” to 10” round duct work must be used with the 1000 CFM remote blower.
D E S I G N E R Installation Instructions O K E A N I TO WA L L Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
D E S I G N E R Installation Instructions O K E A N I TO WA L L Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring.
Installation Instructions ZEPHYRONLINE.COM Internal Blower Preparation Position internal blower inside 2. Secure internal blower to internal 3. Position capacitor box inside hood body so internal blower blower flange by (4) M4*16 screws hood body and secure by (2) collar protrudes through 6” round from internal blower hardware.
D E S I G N E R Installation Instructions O K E A N I TO WA L L Remote Blower Preparation Remove internal blower flange 2. Install remote blower 8” round 3. Install threaded cable lock and from motor housing by (6) screws. collar.
Installation Instructions ZEPHYRONLINE.COM Mounting the Range Hood gap between 6 ” bracket and wall 14-1/2” 9-11/16” min. 26” max. 36” Bottom FIG. B FIG. C FIG. D 1. Measure from cooking surface to desired hood bottom, level and mark line A. (26” minimum from cooking surface) 2.
Page 16
D E S I G N E R Installation Instructions O K E A N I TO WA L L Mounting the Range Hood Upper duct cover attachment screw locations 1-7/8” 7/8” Back View remote blower electrical knockout knockout FIG. E FIG.
Features & Controls ZEPHYRONLINE.COM Touch Controls Blower On/O Display (speed level, delay o , filter clean) Mood Light On/O Adjust 3 Speed Levels Lights Low/Medium/High/O 5 Min Delay O 1. Blower On/O By pressing the blower is switched on and o . When switched on, the blower starts up on speed level 1. 2.
Page 18
D E S I G N E R Features & Controls O K E A N I TO WA L L Touch Controls Ba e Filter Clean Reminder A set of ba e filters are fitted by the factory, these ba e filters are intended to filter out residue from cooking.
Maintenance ZEPHYRONLINE.COM Hood & Grease Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth.
FIG. H Swivel LumiLight LED In the unlikely event that your swivel LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. I) 1.
Wiring Diagram ZEPHYRONLINE.COM VOLTS MAX AMPS COK-E36/42/48CSX CBI-290C 0.8 COK-E36/42/48CBGX CBI-390A 2.1 CBI-600A 2.6 INTERNAL BLOWER CIRCUIT DIAGRAM BODY WHITE YELLOW MOTOR BLUE WHITE BLACK WHITE WHITE WHITE BLACK BLACK BODY Control PC for 48” only REMARKS: CONDENSER 3 uF 250V AC120V 60Hz (CBI-290C) CONDENSER 25uF 250V AC120V 60Hz (CBI-390A/CBI-600A) Okeanito Use, Care, and Installation Guide...
Page 22
D E S I G N E R Wiring Diagram O K E A N I TO WA L L VOLTS MAX AMPS COK-E36/42/48CSX COK-E36/42/48CBGX CBE-1000 6.2 PBN-1000A 5.1 REMOTE BLOWER CIRCUIT DIAGRAM BODY GREEN WHITE WHITE YELLOW BLACK MOTOR BLUE BLUE WHITE...
Troubleshooting ZEPHYRONLINE.COM Possible Problem Possible Cause Solutions After installation, the The power source is not turned Make sure the circuit breaker and the unit doesn’t work. unit’s power is ON. The power line and the cable Check the power connection with the locking connector is not unit is connected properly.
Page 24
D E S I G N E R Troubleshooting O K E A N I TO WA L L Possible Problem Possible Cause Solutions The hood is not Using the wrong size of ducting. Change the ducting to at least 6” or venting out properly.
List of Parts & Accessories ZEPHYRONLINE.COM Description Part Number Replacement Parts Baffle Filter (each) 50210036 LED Bulb, 4W P12010008 Swivel LumiLight LED, 6W Z0B0052 Optional Accessories Duct Cover Extension Z1C-00OK Single Internal Blower CBI-290C / CBI-600A External Blower CBE-1000 In-line Blower PBN-1000A To order parts, visit us online at http://store.zephyronline.com.
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Okeanito Use, Care, and Installation Guide...
Page 29
WWW.ZEPHYRONLINE.COM Okeanito COK-E36CSX, COK-E42CSX, COK-E48CSX, COK-E36CBGX, COK-E42CBGX, COK-E48CBGX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.0101...
Page 30
D E S I G N E R O K E A N I TO M U R Okeanito Guide d’utilisation, d’entretien et d’installation...
Page 31
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ............... 4-6 Types d’avertissements de sécurité ............. 4 Sécurité générale ................4-5 Opération ................... 6 Exigences électriques ................. 6 Déclaration d’interface de la Federal Communication Commission ... 6 Liste de matériel .................. 7 Instructions d’installation ..............8-16 Feuille de calcul pour le conduit d’aération .........
D E S I G N E R Consignes de sécurité O K E A N I TO M U R LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très AVERTISSEMENT importantes. Ce manuel contient de nombreux messages de sécurité relatifs à...
Page 33
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LE RISQUE DE BLESSURE AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DES PERSONNES EN CAS D’INCENDIE DE GRAISSE SUR LE DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES AUX HAUT DE LA CUISINIÈRE, RESPECTEZ CE QUI SUITa: PERSONNES, RESPECTEZ CE QUI SUIT: a) DES FLAMMES PLUS INTELLIGENTES avec un couvercle bien...
D E S I G N E R Consignes de sécurité O K E A N I TO M U R LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples.
Liste de matériel ZEPHYRONLINE.COM Pièces fournies Paquet de matériel M4 * 38 po x 10 Quantité Partie Hotte Filtres à chicanes (modèles 36 po et 42 po) Filtres à chicanes (modèle 48 po) Vis de réglage x 3 LumiLight LED pivotante, 6W M4 * 8 x 10 Rondelle x 10 (préinstallé...
D E S I G N E R Instructions d’installation O K E A N I TO M U R Feuille de calcul pour le conduit d’aération Longueur x Longueur x Pièces de conduit Pièces de conduit T otal T otal Nombre utilisé...
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un minimum de conduits ronds de 6” doit être utilisé pour maintenir une efficacité maximale du débit d’air avec le ventilateur interne de 290/600 CFM. Un minimum de conduits ronds de 8” à 10” doit être utilisé avec le ventilateur à distance de 1000 CFM.Les conduits flexibles peuvent restreindre le débit d’air jusqu’à...
D E S I G N E R Instructions d’installation O K E A N I TO M U R Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte Vue de face Vu de dessous 10 po 36 po, 42 po, 48 po Vue de dessus Vue de côté L/C du recouvrement Recouvrement de conduit standard min. : 30-1/2 po max. : 49-1/2 po 10 po Pièce de prolongement Z1C-00OK min.
D E S I G N E R Instructions d’installation O K E A N I TO M U R Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette l’insert doit être correctement mise à...
Instructions d’installation ZEPHYRONLINE.COM Préparation du ventilateur interne Positionnez le ventilateur interne 2. Fixez le ventilateur interne à la 3. Positionnez le boîtier du à l’intérieur du corps de la hotte bride du ventilateur interne à condensateur à l’intérieur du de manière à ce que le collier du l’aide de (4) vis M4*16 du matériel corps de la hotte et fixez-le ventilateur interne dépasse de...
D E S I G N E R Instructions d’installation O K E A N I TO M U R Préparation du ventilateur à distance Retirez la bride interne du 2. Installez le collier rond de 8 po du 3. Installez le verrou de câble fileté ventilateur du boîtier du moteur à...
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte de cuisinière Sommet espace entre le support et le mur 14-1/2 po 9-11/16 po min. 26 po max. 36 po FIG. B FIG. C FIG. D 1. Mesurez de la surface de cuisson au fond de la hotte désiré, nivelez et marquez la ligne A. (26 po minimum de la surface de cuisson) 2.
Page 44
D E S I G N E R Instructions d’installation O K E A N I TO M U R Montage de la hotte de cuisinière Emplacements des vis de fixation du couvercle de conduit supérieur 7/8 po 1-7/8 po Vue arrière Entrée défonçable Entrée défonçable...
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles Ventilateur Marche/Arrêt A cheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumière d'ambiance activée/désactivée Choix de 3 vitesses Lumière: Bas/Moyen/Élevé/Désactivé Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à...
Page 46
D E S I G N E R Fonctionnalités et commandes O K E A N I TO M U R Commandes tactiles Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre à graisse Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure.
LumiLight LED pivotante Dans le cas peu probable où votre LumiLight LED pivotante tomberait en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Consultez la page Liste des pièces et accessoires pour les numéros de pièces et les coordonnées.
Schéma de câblage ZEPHYRONLINE.COM Ampérage VOLTS maximal COK-E36/42/48CSX CBI-290C 0.8 COK-E36/42/48CBGX CBI-390A 2.1 CBI-600A 2.6 Schéma de câblage du ventilateur interne CORPS BLANC JAUNE ROUGE MOTEUR BLEU BLANC NOIR BLANC BLANC BLANC NOIR NOIR CORPS PC de commande pour 48 po seulement Remarques :Condensateur 3uF 250VCA ADAPTÉ...
Page 50
D E S I G N E R Schéma de câblage O K E A N I TO M U R Ampérage VOLTS COK-E36/42/48CSX maximal COK-E36/42/48CBGX CBE-1000 6.2 PBN-1000A 5.1 Schéma de câblage du ventilateur interne CORPS BLANC VERT JAUNE BLANC NOIR ROUGE...
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions Après l’installation, La source d’alimentation n’est pas Assurez-vous que le disjoncteur et l’appareil ne allumée. l’alimentation de l’unité sont allumés. fonctionne pas. La ligne électrique et le Vérifiez que la connexion d’alimentation connecteur de verrouillage du avec l’unité...
Page 52
D E S I G N E R Dépannage O K E A N I TO M U R Problème possible Cause possible Solutions Le ventilateur Le connecteur de la lumière LED Connectez le connecteur de la lumière fonctionne, mais pas est déconnecté.
Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Okeanito Guide d’utilisation, d’entretien et d’installation...