D E S I G N E R Safety Information T R A P E Z E I S L A N D READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. WARNING We have provided many important safety messages in this manual for your appliance.
Page 5
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and...
D E S I G N E R Safety Information T R A P E Z E I S L A N D READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
D E S I G N E R Installation Instructions T R A P E Z E I S L A N D Ducting Calculation Sheet Equivalent number Equivalent number Duct pieces Duct pieces length x used Total length x used Total 3- 1/ 4”...
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round duct work must be used to maintain maximum air flow efficiency with the 290/600 CFM internal blower. A minimum of 8” to 10” round duct work must be used with the 1000 CFM remote blower.
D E S I G N E R Installation Instructions T R A P E Z E I S L A N D Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option.
Installation Instructions ZEPHYRONLINE.COM Hood Specifications Top View Side View 32” Standard Duct Cover Min 34” - Max 51- ” Z1C-00TP Extension Min 47” - Max 72” ” Ceiling Bracket Front View ” 10” ” 13/16 9” ” ” ” FRONT ”, 53- ”, 59- ”...
D E S I G N E R Installation Instructions T R A P E Z E I S L A N D Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring.
Installation Instructions ZEPHYRONLINE.COM Internal Blower Preparation Remove internal blower flange 2. Secure internal blower to internal 3. Secure AC power wiring box to from motor housing by (6) screws. blower flange by (4) M4*16 screws internal blower flange by (2) M4*8 from internal blower hardware.
D E S I G N E R Installation Instructions T R A P E Z E I S L A N D Remote Blower Preparation Remove internal blower flange 2. Secure AC power box and remove 3. Secure AC power ground wire from motor housing by (6) screws.
Installation Instructions ZEPHYRONLINE.COM Mounting the Range Hood 1. Determine the location for mounting the hood. Mark centerlines front to back and left to right of hood placement. Place supplied paper Tabs template on ceiling and center Add Blockings marked center lines with template center lines.
Page 16
D E S I G N E R Installation Instructions T R A P E Z E I S L A N D Mounting the Range Hood FIG. D FIG. E 7. Determine desired height of hood, measure and select either 27-3/8” or 35-3/8” angle brackets. Position and attach angle brackets type A and B to the motor housing as shown using (8) M4*6 screws, (2) for each angle bracket.
Installation Instructions ZEPHYRONLINE.COM Telescopic Rod & Utensil Rail Installation Telescopic Rod Installation (FIG. F) 1. Install telescopic rod (thicker end down) into coupler on top of hood screws and secure by (1) M4*4 set screw for each rod. 2. Extend inner telescopic rod to ceiling coupler and attach by (1) M4*4 set screw for each rod.
D E S I G N E R Features & Controls T R A P E Z E I S L A N D Touch Controls Blower On/O Display (speed level, delay o , filter clean) Lights Low/Medium/High/O Adjust 3 Speed Levels 5 Min Delay O 1.
Page 19
Features & Controls ZEPHYRONLINE.COM Touch Controls Ba e Filter Clean Reminder A set of ba e filters are fitted by the factory, these ba e filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean.
D E S I G N E R Features & Controls T R A P E Z E I S L A N D Optional RF Remote Control FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Page 21
The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. H. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote.
D E S I G N E R Maintenance T R A P E Z E I S L A N D Hood & Grease Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ►...
FIG. J Swivel LumiLight LED In the unlikely event that your swivel LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. K) 1.
D E S I G N E R Wiring Diagram T R A P E Z E I S L A N D VOLTS MAX AMPS CTP-E36/48/54/60CSX CBI-290C 0.8 CBI-390A 2.1 CBI-600A 2.6 INTERNAL BLOWER CIRCUIT DIAGRAM BODY WHITE YELLOW MOTOR BLUE BLACK...
Page 25
Wiring Diagram ZEPHYRONLINE.COM VOLTS MAX AMPS CTP-E36/48/54/60CSX CBE-1000 6.2 PBN-1000A 5.1 REMOTE BLOWER CIRCUIT DIAGRAM BODY WHITE GREEN WHITE YELLOW BLACK MOTOR BLUE BLUE BLACK WHITE BODY Control PC for 48”, 54”, 60” only REMARKS: CONDENSER 15 uF 370V AC120V 60Hz (CBE-1000) CONDENSER*2 25uF 250V AC120V 60Hz (PBN-1000A) Trapeze Use, Care, and Installation Guide...
D E S I G N E R Troubleshooting T R A P E Z E I S L A N D Possible Problem Possible Cause Solutions After installation, the The power source is not turned Make sure the circuit breaker and the unit doesn’t work.
Page 27
Troubleshooting ZEPHYRONLINE.COM Possible Problem Possible Cause Solutions The hood is not Using the wrong size of ducting. Change the ducting to at least 6” or venting out properly. higher for the internal blower and 8” or higher for the external blower. The hood might be hanging to Adjust the distance between the cooktop high from the cook top.
D E S I G N E R List of Parts & Accessories T R A P E Z E I S L A N D Description Part Number Replacement Parts Baffle Filter (each) 50210039 Swivel LumiLight LED, 6W Z0B0052 Optional Accessories Duct Cover Extension Z1C-00TP...
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Trapeze Use, Care, and Installation Guide...
Page 31
WWW.ZEPHYRONLINE.COM Trapeze CTP-E36CSX, CTP-E48CSX, CTP-E54CSX, CTP-E60CSX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.0101...
Page 32
D E S I G N E R T R A P E Z E Î L E Trapeze Guide d’utilisation, d’entretien et d’installation...
Page 33
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ............... 4-6 Types d’avertissements de sécurité ............. 4 Sécurité générale ................4-5 Opération ................... 6 Exigences électriques ................. 6 Déclaration d’interface de la Federal Communication Commission ... 6 Liste de matériel .................. 7 Instructions d’installation ..............8-17 Feuille de calcul pour le conduit d’aération .........
D E S I G N E R Consignes de sécurité T R A P E Z E Î L E LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très AVERTISSEMENT importantes. Ce manuel contient de nombreux messages de sécurité relatifs à...
Page 35
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LE RISQUE DE BLESSURE AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DES PERSONNES EN CAS D’INCENDIE DE GRAISSE SUR LE DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES AUX HAUT DE LA CUISINIÈRE, RESPECTEZ CE QUI SUITa: PERSONNES, RESPECTEZ CE QUI SUIT: a) DES FLAMMES PLUS INTELLIGENTES avec un couvercle bien...
D E S I G N E R Consignes de sécurité T R A P E Z E Î L E LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples.
Liste de matériel ZEPHYRONLINE.COM Pièces fournies Paquet de matériel #6 * 2 po x 4 M4 * 6 x 36 M4 * 38 x 4 Quantité Partie Hotte Filtres à chicanes LumiLight LED pivotant, 6W (préinstallé) (modèle 48, 54, 60 po) LumiLight LED pivotant, 6W M4 * 8 x 12 (préinstallé) (modèle 36 po)
D E S I G N E R Instructions d’installation T R A P E Z E Î L E Feuille de calcul pour le conduit d’aération Longueur x Longueur x Pièces de conduit Pièces de conduit T otal T otal Nombre utilisé...
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un minimum de conduits ronds de 6” doit être utilisé pour maintenir une efficacité maximale du débit d’air avec le ventilateur interne de 290/600 CFM. Un minimum de conduits ronds de 8” à 10” doit être utilisé avec le ventilateur à distance de 1000 CFM.Les conduits flexibles peuvent restreindre le débit d’air jusqu’à...
D E S I G N E R Instructions d’installation T R A P E Z E Î L E Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte Vue de haut Vue de côté 32 po Recouvrement de conduit standard Min 34 po - Max 51- Pièce de prolongement Min 47 po - Max 72 po Support de plafond Vue de face 10 po 13/16 9 po...
D E S I G N E R Instructions d’installation T R A P E Z E Î L E Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette l’insert doit être correctement mise à...
Instructions d’installation ZEPHYRONLINE.COM Préparation du ventilateur interne Retirez du boîtier du moteur la 2. Fixez le ventilateur interne à la 3. Fixez la boîte de raccordement bride du ventilateur interne, fixée bride du ventilateur interne à c.a. à la bride du ventilateur en place à...
D E S I G N E R Instructions d’installation T R A P E Z E Î L E Préparation du ventilateur à distance Retirez du boîtier du moteur la 2. Fixez la boîte électrique c.a. 3. Fixez le fil de mise à la terre bride du ventilateur à...
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte de cuisinière 1. Déterminez l’emplacement de montage de la hotte. Marquez les lignes médianes de l’avant vers Onglets l’arrière et de gauche à droite du placement de la hotte. Placez Ajouter le gabarit en papier fourni sur des blocages le plafond et centrez les lignes centrales marquées avec les lignes...
Page 46
D E S I G N E R Instructions d’installation T R A P E Z E Î L E Montage de la hotte de cuisinière FIG. D FIG. E 7. Déterminez la hauteur désirée de la hotte, mesurez et sélectionnez des supports d’angle de 27- 3/8 po ou 35-3/8 po.
Instructions d’installation ZEPHYRONLINE.COM Installation de la tige télescopique et du rail à ustensiles Installation de la tige télescopique (FIG. F) Vis de 1. Installez la tige télescopique (extrémité la plus épaisse vers le bas) réglage dans le coupleur sur le dessus de la hotte et fixez-la avec (1) vis de réglage M4*4 pour chaque tige.
D E S I G N E R Fonctionnalités et commandes T R A P E Z E Î L E Commandes tactiles Ventilateur Marche/Arrêt A cheur (Vitesse, arrêt à retardement, nettoyage des filtres) Lumière: Bas/Moyen/Élevé/Désactivé Choix de 3 vitesses Arrêt à...
Page 49
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres.
D E S I G N E R Fonctionnalités et commandes T R A P E Z E Î L E Télécommande RF en option Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement.
Page 51
être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. H. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile. Remarque: le support de télécommande ne charge pas la télécommande RF.
D E S I G N E R Entretien T R A P E Z E Î L E Nettoyage de la hotte et du filtre à graisse Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ►...
LumiLight LED pivotante Dans le cas peu probable où votre LumiLight LED pivotante tomberait en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Consultez la page Liste des pièces et accessoires pour les numéros de pièces et les coordonnées.
D E S I G N E R Schéma de câblage T R A P E Z E Î L E Ampérage Volts maximal CTP-E36/48/54/60CSX CBI-290C 0.8 CBI-390A 2.1 CBI-600A 2.6 Schéma de câblage du ventilateur interne CORPS BLANC JAUNE ROUGE MOTEUR BLEU...
Schéma de câblage ZEPHYRONLINE.COM Ampérage Volts maximal CTP-E36/48/54/60CSX CBE-1000 6.2 PBN-1000A 5.1 Schéma de câblage du ventilateur à distance CORPS BLANC VERT BLANC JAUNE NOIR ROUGE MOTEUR BLEU BLEU ROUGE NOIR BLANC CORPS PC de commande pour 48 po, 54 po, 60 po seulement Remarques :Condensateur 15uF 370VCA ADAPTÉ...
D E S I G N E R Dépannage T R A P E Z E Î L E Problème possible Cause possible Solutions Après l’installation, La source d’alimentation n’est pas Assurez-vous que le disjoncteur et l’appareil ne allumée. l’alimentation de l’unité sont allumés. fonctionne pas.
Page 57
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions Le ventilateur Le connecteur de la lumière LED Connectez le connecteur de la lumière fonctionne, mais pas est déconnecté. LED. les lumières. Lumière LED défectueuse. Changer la lumière LED. La hotte ne s’évacue Utiliser la mauvaise taille de Changez le conduit à...
D E S I G N E R Liste des pièces et accessoires T R A P E Z E Î L E La description Numéro d’article Pièces de rechange Filtre à chicane (chacun) 50210039 LumiLight LED pivotante, 6W Z0B0052 Accessoires optionnels Rallonge de couvercle de conduit Z1C-00TP...
Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 Trapeze Guide d’utilisation, d’entretien et d’installation...