REFRIGERANT SYSTEM
The refrigerant system of the new MF 52-62 Flakers
Split versions consists off:
1
Refrigerant inlet flared male connection (3/8")
2
Refrigerant outlet flared male connection
(1/2" MF 52 and 5/8" MF 62)
3
Liquid solenoid valve
4
Thermostatic expansion valve (Flica TMVX ø
2.0 mm - 2 pcs on MF 62)
5
Refrigerant evaporating pressure regulating
valve (Danfoss KVP 12 on MF 52 and
Danfoss KVP 22 on MF 62)
The refrigerant system is supplied completely sealed
with two copper caps located on the flared nuts and
pre-charged with a limited quantity of R404a.
5