Technical Data; Ul-Data - DOLD SAFEMASTER S UH 6932 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data

Frequency Measuring Input E1 and E2
Supply voltage:
Input current:
Output:
HIGH-level:
LOW-level:
Min. pulse duration e. g.
on and off time:
Input frequency:
Response value:
Measuring accuracy:
Stability of the setting
threshold at variation of
auxiliary voltage and
temperature:
Hysteresis:
Reaction time of
Frequency monitoring:
Alarm delay t
:
v
Start up time delay t
:
A
Reset delay t
:
F
Switchover time period t
:
U
Accuracy of the
adjustable times:
Time between connection
of auxiliary supply and
ready to mesure:
Auxiliary circuit (A1-A2)
Auxiliary voltage U
:
H
Voltage range:
Nominal consumption:
Short-circuit protection:
Overvoltage protection:
Duty-cycle Reset button:
Output
Contacts:
Contact type:
Thermischer Strom I
:
th
Switching capacity
to AC 15:
to DC 13:
to DC 13:
Electrical life
at 5 A, AC 230 V cos ϕ = 1:
Short circuit strength
max. fuse rating:
Mechanical life:
Semiconductor
monitoring output:
Analogue output:
DC 24 V (provided by the device)
Max. 30 mA
As option PNP or NPN
DC 10 V ... DC 26.4 V
< DC 2 V
75 µs
< 3 kHz
Adjustable from 1 Hz ... 2 kHz
< ± 2 %
< ± 1 %
Adjustable from 2 ... 10 %
of the set response value
Duration of 1 cycle (inverse value of
adjusted frequency) + 10 ms
+ adjusted response delay
Adjustable from 0 ... 100 s
Adjustable from 0 ... 100 s
Adjustable from 0 ... 100 s
Adjustable from 0 ... 100 s
< ± 5 %
Approx. 1.5 s (with start up delay is 0)
DC 24 V
The power supply shall meet the
requirements of SELV / PELV
0.8 ... 1.1 U
H
Typ. 3.2 W
Internal PTC
Internal VDR
> 1.2 s
2 NO contacts
Relay forcibly guide
8 A
(see current limit curve)
3 A / AC 230 V
IEC/EN 60947-5-1
2 A / DC 24 V
IEC/EN 60947-5-1
4 A / DC 24 V at 0.1 Hz
> 2.2 x 10
switch. cycl. IEC/EN 60947-5-1
5
10 A gG / gL
IEC/EN 60947-5-1
20 x 10
switching cycles
6
DC 24 V, 50 mA, plus switching
2 ... 10 V, max. 10 mA
Technical Data
General Data
Nominal operating mode:
Temperature range
operation:
storage:
Altitude:
Clearance and creepage distance
Rated impuls voltage /
pollution degree:
EMC
Interference suppression:
Degree of protection:
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire connection:
Wire fixing:
Mounting:
Weight:
Dimensions
Width x height x depth:

UL-Data

The safety functions were not evaluated by UL. Listing is accomplished
according to requirements of Standard UL60947, "general use
applications"
Standards:
- ANSI/UL 60947-1, 5
Edition (Low-Voltage Switchgear and Controlgear
th
Part1: General rules)
- ANSI/UL 60947-5-1, 3
Edition (Low-Voltage Switchgear and Controlgear
th
Part5-1: Control circuit Devices an Switching Elements - Electro-
mechanical Control Circuits Devices)
- CAN/CSA-C22.2 No. 60947-1-13, 2
gear and Controlgear - Part1: General rules)
- CAN/CSA-C22.2 No. 60947-1-14, 1
gear and Controlgear - Part5-1: Control circuit Devices an Switching
Elements - Electromechanical Control Circuits Devices)
Nominal voltage U
:
N
DC 24 V:
Switching capacity:
Semiconductor monitoring
outputs:
Switching capacity
Relay output
device free-standing:
Ambient temperature 60°C:
Device mounted without
distances heated by devices
with same load:
Ambient temperature 55°C:
Ambient temperature 60°C:
Wire connection
Ambient temperature
60°C, 4A bzw. 55°C, 5A:
Ambient temperature
60°C, 8A:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo
24
Continuous operation
- 20 ... + 60°C
- 20 ... + 70°C
< 2000 m
4 kV / 2
IEC 60664-1
EN 61800-3, IEC/EN 61326-3-1
Limit value class B
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
Thermoplastic with V0 behaviour
according to UL subject 94
Amplitude 0,35 mm
frequency 10 ... 55 Hz IEC/EN 60068-2-6
20 / 060 / 04
IEC/EN 60068-1
EN 50005
DIN 46228-1/-2/-3/-4
Captive slotted screw
DIN-rail
IEC/EN 60715
Approx. 320 g
45 x 107 x 121 mm
Edition (Low-Voltage Switch-
nd
Edition (Low-Voltage Switch-
st
Device must be supplied with a Class 2 or
a voltage / current limited power supply.
24Vdc, 50mA, pilot duty
Pilot duty B300, R300
8A 250Vac G.P.
8A 24 Vdc
Pilot duty B300, R300
5A 250Vac G.P.
5A 24 Vdc
Pilot duty C300, R300
4A 250Vac G.P.
4A 24 Vdc
Min. 75°C aluminum or copper conductors
Min. 90°C aluminum or copper conductors
UH 6932 / 23.12.20 en / 337A
EN 55011

Publicité

Chapitres

Table des Matières
loading

Table des Matières