Circuit Diagram (example YRHK01M/K)

3
14
2
11
12
1
6
22
4
21
24
5
20
32
31
19
11
52
10
51
54
9
8
42
41
7
17
62
61
18
16
15
red
24
yellow
23
22
green
21
12
M11413_b
Fig. 5:
Blocking function when
deactivated:
Magnet released, actuator
inserted, key removed or
inserted, door closed

Alternative STS/K Units

The following overview shows some examples of alternative STS/K units
with normal and inverted functions:
normal
M10BM/K
M11BM/K
M12BM/K
M10B01M/K
M10B02M/K
RX10BM/K
The units specified offer the same functions, only the operating sequence
is different. In the event of switch / locking modules the monitored module
logically changes.

Diagnostic Coverage (DC)

When using an actuator module K/K above an electrical STS/K module
such as switch module RX/K or solenoid locking module YRH/K, the dia-
gnostic coverage (DC value) needs to be determined by the mechanical
STS/K module only in the first step.
To determine the diagnostic coverage of a STS/K unit with inverted function
an overview of the functionally identical STS/K units with normal function is
provided in alternative STS/K units. The respective diagnostic coverages
can be found in the SAFEMASTER STS/K design guide.
The diagnostic function of the electrical STS/K module is to be considered
as 1 or 2-channel system, depending on the design of the circuits. The DC
value of the mechanical STS/K component is included in the calculation
of the diagnostic coverage according to EN ISO 13849-1 to assess the
key transfer function as subsystem. For more information on this subject
refer to the SAFEMASTER STS/K design guide.
Switching logic
3
2
3
1
6
4
6
5
19
20
11
9
11
10
7
8
17
18
U
N
15
16
closed
open
The state shown in Figure 5 does
not depend on the control signal of
the magnet.
If the control signal is applied and the
actuator removed the locking module
drops to the state of Figure 4.
If no signal is applied and the
locking module is removed the
locking module changes to the state
of Figure 3.
inverted
MK01M/K
MK11M/K
MK21M/K
M10K01M/K
M20K01M/K
RXK01M/K

Technical Data

Enclosure:
Internal parts and inserting slots:
Ambient temperature:
Application:
ATTENTION !
!
To avoid wrong usage (e.g. by overload, mounting position
or usage in acid, alkaline or other hostile ambient condi-
tions) the limitations of the product have to be observed.
Please check in advance if your application requires the
usage of the more robust stainless steel model of SAFE-
MASTER STS. The requirements of the mounting and ope-
rating instruction must be fulfilled.

Dimension [mm]

40
Actuator module K/K
Actuator module K/K

Variants and Accessories

Devices with several actuators
If several actuators are needed for an application, for instance, for the
implementation of categories 4 or 3, several actuator modules K/K can also
be installed next to each other. However, they cannot be connected with
an actuator module B/K as is the case with normally functioning versions.
An example of an STS/K unit with double actuator is the MKK01M /K or
the RXKK01M/K. When connecting two actuator modules, care should be
taken that the introduction of both actuators into the associated actuator
modules takes place at the same time. As an option, the bottom actuator
can be introduced first and then the top one later. If the actuators are both
coded the same, it has no significance for the assembly and function of
the STS/K unit.

Ordering Designation

Actuator module K/K
Article number: 0066793
11
SAFEMASTER STS/K Actuator module K / 08.09.20 en / 288A
PA + GF
Stainless steel
V4A / AISI 316 / AISI 630
- 25 °C to + 60 °C
only as part of a unit of the
SAFEMASTER STS/K series
30
42,5
51