Technical Data

Mechanical Data
Enclosure:
General Data
Temperature range:
Storage range:
Version:

Dimensional Drawings [mm]

Variants and Accessories

The padlock module W has an inverted working principle compared to
padlock module V and is used to lock an access or switch with the help of
a padlock. To release a process, the key of the padlock module W must be
inserted. Padlock modul W are ideally suited for inverted applications with
the actuator modules K and E.

Ordering Designation

Padlock module V
Article number: 0061874
Padlock module W
Article number: 0063985
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail: dold-relays@dold.com • internet: http://www.dold.com
Stainless steel V4A / AISI 316L
- 40°C to + 100°C
- 40°C to + 100°C
Padlock module V:
For the release of the upper module
and locking of the lower module the
non-removable key must be pulled
out; option of hanging up 1 to 3
padlocks
Padlock module W:
Inverted design of padlock module
V; for the release of the lower and
locking of the upper module then non-
removable key must be pulled out;
option of hanging up 1 to 3 padlocks

Safety Related Data

Data suitable for the PFH
summation method according to
D
EN ISO13849-1:2016
Data
according
to EN
ISO13849-
1:2016
Category
2
PL
d
PFH
1,061E-09
D
T
20
10D
CCF
65-100
required
B
2.000.000
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostic
60%
coverage DC
Test interval
according to
1 / year
ISO14119
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2
actuators must be used
PFH
:
A single module has no function. As a result, an individual
D
module cannot have any safety-related characteristic values.
The safety-related characteristic data in the table only serve
to determine the values of a unit into which it is integrated.
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
D
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
P .O. Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356
8
SAFEMASTER STS Padlock modules V and W / 09.07.20 en / 270A
Padlock modules V and W
3
3
d
e
6,84592E-10 5,44569E-10 1,00122E-10
20
20
85-100
85-100
2.000.000
2.000.000
365
365
24
24
1
1
8760
8760
60%
90%
1 / year
1 / month
+ ... PFH
D1
4
e
20
85-100
2.000.000
365
24
1
8760
99%
1 / month
Dn