Technical Data

Radio
Conformity:
Carrier frequency:
Frequencies:
Frequency range (without licence): 433.1000 ... 434.6750 MHz
Max. HF transmitter power:
Min. HF transmitter power:
Distance:
Aerial:
Sensitivity:
*
The distance can vary with the ambient conditions of the remote
)
control and the receiver aerial (roof construction, metal walls etc.)
Power supply
Nominal voltage U
:
N
Voltage range
at max. 5% residual ripple:
Nominal consumption:
Control voltage on
S11, S13, S31, S33:
Control voltage on
48, 58, OIR, Q25, O0, O1,
O2, O3, O4, O5, O6, O7:
Control current on S12, S14,
S22, S24, S32, S34, S42, IIR,
F0, F1, F2, F3, F4, F5, F6, F7: each approx. 4 mA at U
Min. voltage for active
signals on S12, S14, S22,
S24, S32, S34, S42,
F0, F1, F2, F3, F4, F5, F6, F7: DC 12 V
Max. voltage for
inactive signal on S12, S14,
S22, S24, S32, S34, S42,
F0, F1, F2, F3, F4, F5, F6, F7: DC 4 V
Max. input voltage on
S12, S14, S22, S24, S32,
S34, S42, F0, F1, F2,
F3, F4, F5, F6, F7:
Fusing:
Max. time differece
between input signals
of one fuction
E-stop, Light curtains, Gates:
Two-hand:
ETS 300 220
UHF, ifrequency modulated (FM)
64 channels in the 433 MHz frequency band
12 channels in the 869 MHz frequency band
in the 433 MHz frequency band
869.7125 ... 869.9875 MHz
in the 869 MHz frequency band
10 dBm (10 mW)
in the 433 MHz frequency band
7 dBm (5 mW)
in the 869 MHz frequency band
integrated aerial
-40 dBm (0,0001 mW)
up to 800 m in open area *)
1/2 aerial, impedance 50 Ω,
plug in as accessory
< -100 dBm
DC 24 V
0.85 ... 1.15 U
N
3.6 W
(semiconductor outputs not connected)
approx. DC 23 V pulses,
mean value approx. 7 V at U
N
approx. DC 23 V at U
N
N
DC 30 V
Internal with PTC
3 s
500 ms
Technical Data
Safety output
Contacts
UH 6900.03:
UH 6900.22:
The NO contacts are safety contacts.
The NC contact can only be used as indicator contact!!
Contact type:
Operating time typ. at U
:
N
Ready for start after
power is turned on:
automatic start:
Operating modes
Full safety operation
Manual Start:
automatic restart:
Cross-operation
Manual Start:
automatic restart:
Safety operation with
optional radio control
S32, S34 supplied with power:
Manual Start:
automatic restart:
S32, S34 not supplied with power:
Reset through S42 (after reset
on control device):
Reset through S42
on control device:
Reset through auto start
on control device:
For the start options with additional detection of the IIR input, the delay
1)
time of the safety element connected to this input must be added to the
pick-up times
Switching off time (reaction time)
S12-S14, S22-S24, S32-S34:
Disconnection with active radio
signal (S12-S14, S22-S24,
S32-S34 of 2
nd
device):
Passive disconnection because
of interrupted radio signal:
Nominal output voltage:
Switching of low loads
Min. switching voltage:
Min. switching current:
Min. switching capacity:
Thermal current I
:
th
Switching capacity
to AC 15:
NO contacts:
NC contacts:
to DC 13:
to DC 13 at 0.1 Hz:
Electrical life
to AC 15 at 2 A, AC 230 V:
Permissible switching frequency: max. 1 200 switching cycles / h
Short circuit strength
max. fuse rating:
Mechanical life:
18
3 NO contacts
2 NO contacts, 1 NC contact
Relais, forcibly guided
max. 2,5 s
no operating mode with automatic start
max. 1 s
1)
max. 1,1 s
1)
max. 650 ms
1)
max. 650 ms
1)
max. 70 ms
max. 80 ms
max. 70 ms
max. 700 ms
1)
max. 700 ms
1)
max. 30 ms
max. 200 ms
max. 500 ms
max. AC 250 V
DC: see limit curve for arc-free operation
> 5 V
> 5 mA
> 25 mW
max. 5 A per contact
see quadratic total current limit curve
3 A / AC 230 V
IEC/EN 60 947-5-1
1 A / AC 230 V
IEC/EN 60 947-5-1
2 A / DC 24 V
IEC/EN 60 947-5-1
8 A / DC 24 V
IEC/EN 60 947-5-1
10
switching cycles
5
6 A gG / gL
IEC/EN 60 947-5-1
10 x 10
switching cycles
6
UH 6900 / 01.09.17 en / 891