3V-490058NI – 12/21
The gas type change is only to be carried out by a technician authorized and trained under the responsibility of the
Company VULCAN or our local agent.
Before any intervention, confirm and check with the owner the nature of the gas supplies in the kitchen.
Equip yourself with suitable measuring tools and ensure that they are in working order: combustion products
analyzer, gas water column pressure gauge, gas leak detector, etc.... Without these tools, it is forbidden to
perform all procedures installation, maintenance, gas control... on gas equipment!
Note: The connection / disconnection of the gas supply as well as all maintenance interventions are subject to the
General :
In the following chapters, the different gases are designated by their international codification :
GAS FLOW RATES AND POWERS
See section : Technical characteristics
CHART OF GAS NOZZLES
6/7 and 10 level ovens
Designation
Familly
Natural gas
Burner
Propan
CHANGEOVER FROM ONE GAS TO ANOTHER:
1)
Check the nature of the gas that supplies the kitchen
2)
Configure the oven with the new gas.
- Switch on the oven and turn on the control screen without heating the oven
- Select the "TOOL BOX" menu
- Select the "Technician parameters" screen
- Enter the password : « SAVB »
- Validate "V" : When finished, if the code is correct access the menu in not re-enter the PIN number..
- Changing the type of the gas
CHANGING THE APPLIANCE FROM ONE GAS TO ANOTHER
local laws and regulations in force.
Gas A
Gas E
GAS
Pressure
Type
(mbar) / (inch w.c.)
A
16 - 25 / 6.5 - 10
E (G31)
25 - 38 / 10 - 15
Positioning of the nozzles
Nozzle
Select the zone of the value to be changed
Adjust the gas type with the coder knob (Gas A or Gas E)
Validate the value
Page 9
NATURAL GAS
PROPAN (G31)
NOZZLES
Qty
e
(1/100
mm)
1
580
1
390
Identification of nozzles
Code
148 798
148 799