3V-490058NI – 12/21
Data plate:
Replace the two data plates by the models in the good
configuration (Stick them on the previous model)
On the data plate, the configurations are differentiated in
item "Model" by the two last digits.
V1PJ071E-86
V1PJ071E-96
V1PJ101E-86
V1PJ101E-96
FOUR GAZ
The oven is equipped with a 1.77 m (70 inch) power cord and a plug NEMA L5-15P in single phase. Fig 5E
Connect the plug to the electrical network. Note: Never connect the oven to electrical network if the plug or the power cordon are damaged.
The electric line must be eqquipped with overcurrent-protective appliances 15 A and RCD type AC.
Remark: To avoid risk of disconnection, don't drag the power cord to the ground.
The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position.
All aspects of the installation should be in compliance with current local regulations (In France: NFC 15.100).
The appliance must be connected to the earth. Different electric appliances must also be cross bonded (all metallic structures at the same
potential) using the terminal provided for this purpose located next to the cable gland. Fig 5F
The manufacturer accepts no responsibility whatsoever if these instructions are not followed.
Do not operate any appliance with damaged cord or plug or after the appliance malfunctions or has been damaged in any manner. Return
appliance to the nearest authorized service facility for examination, repair or adjustment.
For use on individual branch circuit only.
CAUTION: Disconnect from power supply before servicing.
To reduce the risk of electric shock, this equipment has a grounding type plug. This plug will only fit into a grounding type outlet. If the plug
does not fit into the outlet, contact a qualified electrician to install proper outlet. Do not change the plug in any way.
Voltage conversion from 120V 1~ to 208V 1~ / 240V 1~
Cord and plug:
Replace by a model complying with the following
requirements
Six feet (1,8m) long. Type SO, STO, SEO, SJO, SJTO,
SJEO, HSO, HSJO, or greater, with a diameter of cord
less than 0.4 inch (10 mm) and terminated by molded on
grounding type attachment plug NEMA L6-15P.
Wiring of teh electrical board terminals:
Disconnect the black wire from the 120V terminal (BK2)
and connect it to the 208V 1
1
(BK4) according to the voltage.
~ terminal
208V 3~
240V 3~
208V 3~
240V 3~
(BK3) or to the 240V
~ terminal