Follow the recommendations below to adjust the quality of the water supply to your oven
Check the free Chlorine (Cl2)
(OPTIONAL = in case of odours)
Yes
≤ 0,2 mg/l
No
Activated carbon filter (1)
No
Chlorides (Cl-)
< 150 mg/l
Yes
Reverse osmosis appliance or filters for
(BRITA PURITY 1200 Clean or similar)
CONTROLLING WATER QUALITY
CHECK THE UNTREATED WATER (Natural or not)
Check the water hardness
Yes
< 100 mg/l
CaCO3
(TH < 10) ?
total demineralization
If it is not possible to
balance the water PH
Don't connect the oven
through Bypass
to the water or Ask for
a PH+ appliance
No
Page 8
Check the Chlorides (Cl-)
No
OR
Chlorides (Cl-)
< 60 mg/l
Reverse osmosis appliance or filters for
Filter for decalcifying
(BRITA PURITY Steam or similar)
Set the filters integral by pass or
use an external by-pass
No
60 < CaCO3 < 80 mg/l
6 < TH < 8
Yes
Check the PH
PH > 6,5
Yes
OK
VULCAN
A division of ITW Food Equipment Group LLC
P.O. Box 696
Louisville, KY 40201
Yes
Chlorides (Cl-)
< 150 mg/l
No
total demineralization
(BRITA PURITY 1200 Clean or similar)
EN
Classical Water softener
(ion-exchanger resin)