Franklin Electric SUBMONITOR CONNECT Manuel D'installation Et D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mod
R/W
RC
Address Name
Bus
438
RW
N
Undr Vlt Enable
439
RW
N
Undr Vlt Level
440
RW
N
Undr Vlt Delay
441
RW
N
Undr Vlt Reset
442
RW
N
Undr Vlt Retry
443
RW
N
Undr Vlt Rst Dly
444
RW
N
Unbl Vlt Enable
445
RW
N
Unbl Vlt Level
446
RW
N
Unbl Vlt Delay
447
RW
N
Unbl Vlt Reset
448
RW
N
Unbl Vlt Retry
449
RW
N
Unbl Vlt Rst Dly
450
RW
N
Rev Phase Enable
451
RW
N
Phase Order
452
RW
N
Underpower
Enable
453
RW
N
Underpower Level 1 to 99; default = 50/65
454
RW
N
Underpower Delay 1 to 120; default = 2/3
455
RW
N
Underpower Reset 0 - Manual
456
RW
N
Underpower Retry 1 to 10; default = 3
457
RW
N
Underpower Rst
Dly
458
RW
N
Ovr Pwr Enable
459
RW
N
Ovr Pwr Level
460
RW
N
Ovr Pwr Delay
461
RW
N
Ovr Pwr Reset
462
RW
N
Ovr Pwr Retry
463
RW
N
Ovr Pwr Rst Dly
Choices/Range
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
75 to 99; default = 90
1 to 120; default = 10
0 - Manual
1 - Automatic (default)
1 to 10; default = 3
1 to 43,200; default = 900
0 - Off (default)
1 - Fault and Alarm
2 - Alarm Only
1 to 25; default = 1
1 to 120; default = 10
0 - Manual
1 - Automatic (default)
1 to 10; default = 3
1 to 43,200; default = 900
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
0 - A B C (default)
1 - A C B
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
1 - Automatic
2- Well Recovery (Pump
only)
1 to 43,200; default = 900
0 - Off
1 - Fault and Alarm (default)
2 - Alarm Only
101 to 200; default = 125
1 to 120; default = 3
0 - Manual
1 - Automatic (default)
1 to 10; default = 3
1 to 43,200; default = 900
Modbus RTU Communication
Description
Undervoltage Protection Enable
Undervoltage Level Percentage
Undervoltage Delay Time in seconds
Undervoltage Reset Method
Undervoltage Automatic Reset Allowed Attempts
Undervoltage Automatic Reset Delay in seconds
Unbalanced Voltage Protection Enable
Unbalanced Voltage Level Percentage
Unbalanced Voltage Delay Time in seconds
Unbalanced Voltage Reset Method
Unbalanced Voltage Automatic Reset Allowed Attempts
Unbalanced Voltage Automatic Reset Delay in seconds
Phase Reversal Protection Enable
Phase Order
Under Power Protection Enable
Under Power Level Percentage
SMS default = 65
Reduced Voltage SMS default = 50
Under Power Delay Time in seconds
SMS default = 3
Reduced Voltage SMS default = 2
Under Power Reset Method
Under Power Automatic Reset Attempts
Under Power Reset Delay in seconds
Over Power Protection Enable
Over Power Level Percentage
Over Power Delay Time in seconds
Over Power Reset Method
Under Power Automatic Reset Attempts
Under Power Reset Delay in seconds
COMMUNICATIONS
45