Limit Mode; Define Limit - Allmatic Clamp assist Instructions De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
ALLMATIC
8.6

Limit Mode

1
00.0
kN
Y
0 s
LIMIT: SET + SAVE
Fig. 10: Limit mode
1 Storage location of the CA
spindle
The clamping force pre-set by the user (reference force) is displayed on the MEE by an LED
Limit
when 90% is reached.
The LED only displays reaching of the limit. There is no protective function to prevent
the clamping force increasing further.
8.6.1

Define Limit

w MEE in limit mode.
1. The button
required value is displayed.
ð Keep pressed: Express setting
ð Touch: Fine adjustment
Clamp assist
2
36.0
kN
Y
Y
10 s
2 Currently set limit of the clamping force
of the corresponding spindle position is to be kept pressed until the
3
00.0
00.0
kN
Y
0 s
Operation | 8
4
1
2
kN
0 s
49 / 294
EN

Publicité

Table des Matières
loading

Table des Matières