8 | Operation
Live
Recording of the current clamping pressures. The last 1200 values are displayed. The measure-
ment rate depends on the transmission interval of the CA spindle. With a constant clamping
force, a value is transmitted every 12 seconds, with an inconstant clamping force every 0.5
seconds.
The live diagram displays the changes in clamping force over the last 1200 values. In this way,
for example, a decrease in clamping force while processing a workpiece can be detected. The
live data are stored when the MEE is in force display mode and is within range. If the mode is
changed, logging is stopped.