Maintenance; Scheduled Maintenance Table; Integrity Check Of Power Supply Cable And Extension - Advance Micromatic M17E Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

MAINTENANCE

The lifespan of the machine and its operating safety are ensured by correct and regular maintenance.
The following chart provides the scheduled maintenance. The intervals shown may vary according to particular working conditions,
which are to be defi ned by the person in charge of the maintenance.
WARNING!
Maintenance procedures must be performed with the machine switched off and the power supply cable
disconnected from the mains.
Moreover, carefully read the instructions in Safety chapter.
All scheduled or extraordinary maintenance procedures must be performed by qualifi ed personnel, or by an authorized Service
Center.
This manual describes only the easier and most common maintenance procedures.
NOTE
For other maintenance procedures contained in the scheduled maintenance chart, refer to the Service Manual that can
be consulted at any Service Center.

SCHEDULED MAINTENANCE TABLE

Procedure
Squeegee cleaning
Brush cleaning
Tank and vacuum grid cleaning
Squeegee blade check and replacement
Solution fi lter cleaning
Screw and nut tightening check
Vacuum system motor carbon brush check or replacement
(1)
And after the fi rst 8 working hours
(2)
This maintenance operation must be performed by Advance authorized Service Center.

INTEGRITY CHECK OF POWER SUPPLY CABLE AND EXTENSION

Carefully check if the power supply cable, the extension and the plugs are worn or damaged.
If necessary, have them replaced by the Service Center.
16
INSTRUCTIONS FOR USE
909 5855 000(4)2009-11
Daily or after us-
Weekly
ing the machine
Micromatic™ M17E
Every six
Yearly
months
(1)
(2)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

908 7058 020

Table des Matières