MAINTENANCE (CONTINUED)
6. Slowly pull the starter cord, until resistance is felt. This indicates that the piston is moving upward on the
compression cycle, and the intake and exhaust valves are closed. (The piston pushes a small amount of
air from the spark plug hole on compression.)
Use of fuel stabilizers or anti-gumming agents in the fuel system can help prevent the build up of gum and
varnish.
Whenever the unit is stored, be sure that the fuel shut-off valve is in the closed position.
Refer to the engine manual that accompanies this unit for instructions regarding maintenance of engine
components.
by qualified personnel only.
Weld Cables
1. Check condition of weld cables and immediately repair or replace any cables with damaged insulation.
2. Check condition of electrode holder insulating pieces and immediately replace cracked or missing parts.
Every 3 Months
Replace any unreadable labels on the unit. Use compressed air to blow all dust and lint from the ventilation
openings.
Maintenance Schedule
Operation
Check Safety Valve
Drain Tank
Check Oil Level
Clean or Change Air Filter
Check Belt Tightness
Change Oil
22
The Engine is factory set to 3800 RPM with NO load. Never tamper with engine
speed settings or frequency settings. Any governor adjustments should be made
Daily
Monthly
●
●
●
●