To Stop The Compressor; Inspection, Maintenance, And Cleaning - Speedaire 25F538 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instuctions & Parts Manual
Speedaire 2 GALLON
Oilless Air Compressor
(continued)
E
N
3. Blow air out of the blow
G
gun while you turn the Pres-
sure Regulator knob to adjust
L
Pressure Regulator . Turn the
I
Pressure Regulator knob
S
counterclockwise to decrease
H
the PSI, turn it clockwise to
increase the PSI. When the
Regulated Pressure Gauge
shows the pressure that you
want to limit the compressor
to, the Pressure Regulator is
set. (See Figure C.)
4. Between the Pressure Regu-
lator knob and valve body, a
narrow ring acts as a lock-ring
for the knob. Rotate the ring
in a counterclockwise direction
and tighten it against the
knob to secure the setting.(See
Figure C.)
NOTE: When the maximum
air pressure, 100 PSI, is reached
as indicated by the Tank
Pressure Gauge , the motor
will stop. The Compressor will
automatically restart when the
air pressure drops below 85
PSI.(See Figure C.)
TO STOP THE
COMPRESSOR:
1. Push the ON/OFF Power
Switch to its "OFF" position
2. Unplug the Air Compressor
from its electrical outlet. Place
a collector can (not included)
under the Air Tank and turn
the Drain Valve counterclock-
wise.
®
3. Pull out on the Safety
Valve to release all remain-
ing air pressure from the Air
Tank. (See Figure C.) This
will not only drain the air,
but will also drain any
accumulated moisture.
After all air is drained, turn
the Safety Valve clockwise.
4. Squeeze the trigger on
the pneumatic tool to
release any remaining air
pressure from the tool.
Then disconnect the air hose
from the tool, and store the
tool in a clean, dry, safe
location out of reach of
children.
5. Remove any moisture in
the Tank by opening the
Tank Drain Valve
Then, retighten the Drain
Valve . (See Figure B.)
6. Allow the Air Compressor
to completely cool. Then
store the unit in a clean, dry,
safe location out of reach of
children.
INSPECTION,
MAINTENANCE, AND
CLEANING
Make sure the ON/OFF
Power Switch of the Air
Compressor is in its "STOP"
position, the unit is
unplugged from its electrical
outlet, and air is drained
from the Tank before
performing any inspection,
maintenance, or cleaning
procedures or leaving it
unattended.
6
25F538
Before each use,
inspect the general condi-
tion of the Air Compressor.
Check for loose screws,
misalignment or binding of
moving parts, cracked or
broken parts, damaged
electrical wiring, loose air
fittings, and any other
condition that may affect
the safe operation of the
Compressor. If abnormal
noise or vibration occurs,
have the problem corrected
before further use.Do not
use damaged equipment.
Daily, purge the Air Tank of
all air and moisture to
prevent corrosion. To do so,
slowly and carefully unscrew
(no more than four threads)
the Tank Drain Valve
Then, firmly re-tighten the
Drain Valve.
All maintenance, service, or
repairs not mentioned in this
manual must only be
performed by a qualified
service technician.
To replace the Fuse ,
unscrew the fuse and
replace with a 250V, 3A fuse.

Publicité

Table des Matières
loading

Table des Matières