INSTALLATION INSTRUCTIONS (CONTINUED)
Lubrication
1. Oil is NOT mixed with the gasoline, however adequate oil supply is necessary for proper engine lubrication.
Refer to the Engine Manual for SAE, API and fill quantity specifications.
2. Remove pump fill plug and fill pump with 14.1 oz. of oil.
Use full synthetic motor oil like Mobil 1
Additives in regular oil can cause valve deposits and reduce pump life. For pumps with an oil sight glass, oil
level can be monitored and maintained as shown in Figure 4.
Figure 4
Battery Set-Up and Connections
This unit DOES NOT come with a battery or battery cables. A 12 Volt battery must be connected to the unit.
The 12 Volt battery must be at least a U group size number. Using at least 8 AWG battery cables, a connection
must be made from the starter solenoid on the Honda engine to an in-line 30 amp fuse, and then to the positive
terminal of the 12 Volt battery. From the negative battery terminal, a connection must be made to the ground
screw located on the left side of the frame. Please refer to the wiring schematics in this manual. If you have any
questions, please contact customer service at 1-888-606-5587.
Grounding
1. Use the ground terminal and wing nut on the frame to connect the unit to a suitable ground source. Securely
fasten the end terminal an approved ground wire (not provided) to the ground terminal on the frame. Tighten
the washer and wing nut on top of the ground wire end terminal.
2. The ground wire should be made of #8 gauge wire. Do not use wire with a higher gauge number. Higher
gauge numbers indicate thinner wire, which may not provide an adequate ground path.
3. The other end of the ground wire must be securely fastened to an approved ground source.
The following are ground sources approved by the National Electric Code. Other ground sources may be
acceptable. Refer to the National Electric Code and local regulations for further ground source information. If not
sure of regulations or procedures, obtain assistance from a qualified (licensed or certified) electrical technician.
a. An underground water pipe at least ten feet in length
b. A non-corrosive underground pipe at least eight feet in length and 3/4 inch diameter
c. A steel or iron underground rod at least eight feet in length and 5/8 inch diameter
d. A non-ferrous rod at least eight feet in length, 1/2 inch in diameter, and approved for grounding purposes
Any rod or pipe used for grounding must be driven to eight feet deep or buried in the deepest possible trench.
Plumbing
The SDR8CG00 and SDR8CGW0 models include a 2 gallon accumulator tank. Prior to operation of this unit, the
accumulator tank MUST be connected to your remote air tank. Connect the remote air tank to the accumulator
tank with a minimum of 1/2 inch NPT fittings and/or 1/2 inch ID hose rated for AT LEAST 200 psi. This
accumulator tank is not to be removed from the unit for any reason.
10
CHECK ENGINE AND PUMP OIL LEVELS BEFORE OPERATING! Follow lubrication
instructions before operating compressor.
®
10W-30. Do not use regular automotive oil such as 10W-30.
Full
Add Oil
All manufacturer's warranties are void if the battery connections are not made as
specified in this manual.
Do not operate the unit unless the accumulator tank is properly installed.
All manufacturer's warranties are void if the 2 gallon accumulator tank is not
plumbed, and connected as specified in this manual.