- Open the glass door.
- Press and turn the knob to the position of maximum Large flame.
- Light the burner with a long lighter.
- Keep the knob depressed for 20 seconds, to allow time for the safety
valve to act
- Regulate the flame of the burner at the desired power
2.- Starting the engine
Press the switch and place it in position (1) the engine will turn on and
the switch will light
3.- Turning off the burners
To turn off the appliance, simply turn the knob to the off position (0).
It is recommended to close the gas passage of the general supply
network.
4.- Engine shutdown
Press the switch and place it in position (0) the switch will turn off.

2.10. CHECKING THE FUNCTIONING OF THE DEVICE

Once turned on, a check of the operation will be carried out always
following the indications of the country of destination for the installer. It is
the responsibility of the installer to carry out these checks according to
the regulations in force.
Paying special attention to:
1.- Connection nozzle
2.- Sealing
3. Appearance of the flames and Power
4.- Minimum position
5.- Security devices

2.11. CHAIN TENSION

The chain is located on the left side where the entire electrical part is
located, so before removing the side cover proceed to disconnect the
device from the network. To tighten the chain loosen the 4 screws that
take the motor to tighten the chain, and retighten the screws.