1. TECHNICAL SHEET
Category
2H - 2E
2E+
3B/P
3P
A type
Gas
Pres-
sure
(mbar)
G20
20
G30
50
G31
50
The motor works at a voltage of 230V 50Hz
This appliance must be installed in accordance with the regulations in
force, and must only be used in sufficiently ventilated places.
Consult the instructions before installing and using this device.
It is recommended to check the device before installation and verify that
it has not suffered any damage by transportation.
The manufacturer is not responsible if the device is installed without
following the installation instructions or if the user acts without taking into
account the instructions in the manual.
The installation and maintenance operations will be carried out by
qualified technical personnel.
These instructions are only valid if the country symbol appears on the
device, otherwise instructions must be requested.
Remember that parts that have been protected by the manufacturer and
its agent should not be handled by the installer or the user.
12
Pressure
Pressure
mbar
mbar
G20
20
G20 - G25
20 (25)
G30 - G31
50
G31
50
Con-
2ASG
sumption
Flow
(Hi) kW
14.0
m
/h
1.26
3
(Hi) kW
13.4
m
/h
0.38
3
(Hi) kW
14.0
m
/h
0.44
3
Injector
mm
2.00
2.00
1.20
1.25
Model
3ASG
4ASG 5ASG 6ASG 7ASG 8ASG
21.0
28.0
35.0
1.89
2.52
3.15
20.1
26.8
33.5
0.57
0.76
0.95
21.0
28.0
35.0
0.66
0.88
1.10
Primary Air
Consumption
(S/Hi)
Fijo
7.0
Fijo
7.0
Fijo
6.7
Fijo
7.0
42.0
49.0
3.78
4.41
40.2
46.9
1.14
1.33
42.0
49.0
1.32
1.54
56.0
5.04
53.6
1.52
56.0
1.76