Wiring Installation

NOTICE:
Check motor terminal cover or nameplate for
wiring instructions. The essential pump motor facts are
as follows:
1. 3450 rpm
2. Single-phase
3. Dual Voltage, 115/230 on 1 and 1-1/2 hp; 230 V
only on 2 hp motors.
4. 1/2, 3/4, 1, and 1-1/2 hp motors are wired
for 230 Volts as a factory standard.
Step 1:
Remove motor access cover at back of motor.
Step 2:
Feed the grounding wire (green or bare copper) through
the electrical conduit port in the side of the motor. First
connect the ground wire then connect the power supply
wires. Attach the grounding wire to the motor ground
screw (green). Secure wires to prevent electrical shorts.
Step 3:
Connect the incoming power supply wires to the motor
terminal.
Step 4:
Replace and secure motor cover.
NOTE: Single-phase motors rotate counterclockwise
only (when facing suction port) and cannot
be reversed.
MOTOR
NOTICE: A motor operating under normal conditions
maintains its rated performance, assuming a clean,
dry motor with proper ventilation. A dirty motor,
or one "protected" by a burlap or plastic bag,
will overheat.
PRIMING AND START UP
W A R N I N G
NEVER run pump dry. Fill pump with
water before starting pump. Operating pump dry may
cause damage to pump and will void warranty.
W A R N I N G
NEVER run pump against a closed
discharge. This may cause hazardous pressure and risk
of explosion.
Step 1 (Figure 7):
Remove priming port plug from pump.
Step 2:
Open discharge valves and any hoses on discharge
side of pump.
Step 3:
Fill pump with water through the priming port on
top of pump. Allow trapped air to escape for a few
minutes, then add more water until full.
Step 4:
Replace priming port plug and tighten with wrench,
using PTFE tape on pipe threads.
Step 5:
Start the pump. A properly primed pump should
discharge water without air at a consistent pressure.
If the pump does not produce water after five
minutes, stop the pump, release all pressure,
remove priming port plug, add more water, replace
plug, and try again. (Make sure that a foot valve is
properly installed on the suction pipe. See "Suction
Port Connection" (Figure 4).
PRIMING PORT
MAINTENANCE
W A R N I N G
WARNING
electrical power before attempting
maintenance can cause shock, burns,
or death.
W A R N I N G
pump, be sure fuse box leads are
disconnected or power is turned off.
After reassembling the pump, refer to
WARNING
priming instructions before running.
HAZARDOUS PRESSURE!
• Do not run pump against
closed discharge.
• Release all pressure on system
before working on any component.
1-1/2" DISCHARGE PORT
1-1/2" SUCTION PORT
DRAIN PLUG
Figure 7
Failure to disconnect
Before disconnecting