OPERATION

Electrical Connections

Thermal Protection

Run 3-phase motors through a control panel for thermal protection.
Single-phase motors are a continuous-duty type equipped with an automatic resetting heat sensor and may
restart unexpectedly. Heat sensor opening is an indication of motor overloading/overheating, which must
be corrected to extend the life of the pump. Refer to

Wiring Schematic

Manual Schematic (1PH/3PH)
Power Cord
Green
Red
White
GRD.
Red Feed Thru
White Feed Thru
Terminal
Terminal
L3
L2
Stator
Bottom Motor Housing
A-N601
OPERATION
Risk of personal injury or damage to pump or other equipment.
This pump is equipped with a cutting mechanism that has very sharp edges. Use caution when
working on or near these parts. Do not allow anything to enter the pump during testing.
The float or ball portion of the switch must not be obstructed by the pump, the walls of the basin,
the plumbing, or any wiring in the basin as it floats up or down. Contact with obstacles may cause
the pump to continue running without water or to stop running when water is present, damaging
the pump or other property.
Do not run pump dry. If run dry, the surface of the pump will rise to a high temperature that could
cause skin burns if touched, and will cause serious damage to the pump.
1.
Connect the pump to power with correct voltage.
Refer to the pump nameplate.
2. Ensure the gate valve in the discharge line is open.
3. Run water into the basin until the pump is activated.
6
"Troubleshooting" on page 9
Motor
Housing
Cover
Black
Motor
Leads
Black Feed Thru
Terminal
L1
GRD.
Bottom Motor
Housing
for further details.
Automatic Schematic
Power Cord
Power
Cord
Upper Motor
Pins
Green
Housing
White
Red
START
270 uF
1
White
2
RUN
50 uF
White
White
Red
White Feed
Red Feed
Black Feed
Thru Terminals
Thru Terminals
Thru Terminals
( T5 )
( T4 )
Red
START
White
RUN
Black
Relay
( NC )
5
Black
{ T1 }
Thermal
Protector
White TR
Stator
Lead
A-N601