INSTALLATION
Typical Installation
Risk of damage to pump or other equipment.
• The motor on this pump is guaranteed by the manufacturer. In event of failure, it must be returned to an autho-
rized product reseller for review and disposition. Product warranty is void if product is disassembled or reviewed
by any other party.
• Install the pump in a properly developed well. Undeveloped well water often contains abrasives that can damage
the pump.
• Check that the well is deep enough to allow the pump to be set at least 5 ft from the bottom.
• Do not set pump below the casing perforations or well screen unless there is an adequate flow of water over the
motor for cooling purposes is ensured.
• Determine the correct pump setting from the driller's record, taking into account the static water level and the
draw-down at the proposed pumping rate.
INSTALLATION
Typical Installation
Sanitary Well Seal
or Pitless Adapter
Drop Pipe
2
Discharge Pipe
Submersible Cable
Spring-Loaded Check Valve
(Per manufacturer's recommendation)
Safety Cable
Electrical Cable
(secured to drop pipe with tape or clamps every 10ft / 3m)
Torque Arrestor
Well Casing
Spring-Loaded Check Valve at Pump Discharge
Submersible Pump Unit
Suction Screen
Motor
Well Screen or Casing Perforations
See Wiring Diagrams
Spring-Loaded
Check Valve
Pressure Relief Valve
Pressure Gauge
Note: Keep pump at least 5 ft from
bottom of well and above well screen
or casing perforations.
Pressure Tank
Pressure Switch
Gate Valve
Service Pipe