Drive Configuration; Motor Type Selection; Pressure Input Selection (Dip Sw2 - Position 1); Adjusting Pressure Setting - Franklin Electric MONODRIVE UTILITY Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION AND SETUP

Drive Configuration

Drive Configuration
Contact with hazardous voltage could result in death or serious injury.
Do not attempt to modify DIP switch or potentiometer settings until power has been
removed and 5 minutes have passed to allow internal voltage to discharge.
Do not power on or use the drive with the cover removed.

Motor Type Selection

Motor Horsepower Setting (DIP SW1 – Positions 1–5)
Select a single DIP switch from SW1, position 1 - 5 that corresponds with the motor/pump HP being
used and place it in the UP position. The corresponding HP values are printed above the SW1 dia-
gram on the shield.
Selecting none or more than one switch will result in an Invalid Configuration fault.
Franklin Electric 3-Wire Submersible Motor Series (DIP SW1 – Positions 6–8)
When using a Franklin Electric submersible motor, SW1 – Positions 6 through 8 must be set to D
Pressure Input Selection (DIP SW2 – Position 1)
Ensure that the drive is configured for the type of pressure sensor or transducer being used:
If using a standard pressure sensor (included), DIP SW2 Position 1 must be in the PS (down)
position.
If using a 4-20 mA pressure transducer (optional), DIP SW2 Position 1 must be in the XDCR (up)
position.

Adjusting Pressure Setting

IMPORTANT: Monitor pressure gauge during initial startup to ensure system does not over-
pressurize.
Pressure Sensor: The sensor (1) is preset at the factory to 50 psi (3.4 bar), but can be
adjusted by the installer using the following procedure:
Remove the rubber end cap.
Using a 7/32" hex key (2), turn the adjusting screw clockwise to increase pressure and
counter-clockwise to decrease pressure. The adjustment range is between 25 and 80
psi (1.7 and 5.5 bar). Note: 1/4 turn = approximately 3 psi (0.2 bar).
Replace the rubber end cap.
Cover the pressure sensor terminals with the rubber boot provided. Do not place the
boot in direct sunlight.
IMPORTANT: Do not exceed the mechanical stop on the pressure sensor.
22
.
OWN

Publicité

Table des Matières
loading

Table des Matières