The application limits of the DBL-S are determined in function of:
- the door construction
- the door weight
- the door bearings (resistance)
- and the used safety elements (delay-lag distance).
The EU regulations and the country's relevant safety prescriptions have to be complied with.
Door type
H = Travel distance
1.7

Technical data

Mains power supply
Power consumption
Tractive torque
Speed
Ambient temperature
Protection degree
Duty cycle
Maximum weight (H = 5'500 mm)
Noise level
2

Installation

2.1

Checking prior to installation

Should one of the following conditions not be fulfilled, the respective measures have to be taken before installation
work can start.
2.1.1

The surroundings of the door

- Are the planned fastening points for the DBL-S drive unit accessible?
- Have the power supply cables to the DBL-S drive unit as well as to the control and safety elements been installed
according to the plan of installations for the particular object?
- Has the concealed material been embedded in concrete?
0552-999-04a_08.2001.p65
..-K10 S
EMS 55
..-K15 S
Applications outside of the defined limits
are not admissible.
..-K 15 S
230 V; 50/60 Hz; 0,2 kW
max. 200 W
max. 330 N
0,3 m/s
-20 °C up to +70 °C
IP 23
max. 60 % ED
approx. 40 kg
< 70 dB (A)
0552-999/04a
Typ
H = max.
max. door
travel dist-
ance (mm)
5'500
5'500
Warning:
DBL-S
5-19
V max.
weight
open
(kg)
(m/s)
1'200
0,2
800
0,3
..-K10 S
230 V; 50/60 Hz; 0,2 kW
max. 200 W
500 N
0,2 m/s
-20 °C up to +70 °C
IP 23
max. 60 % ED
approx. 40 kg
< 70 dB (A)
V max.
close
(m/s)
0,2
0,3
Tab. 1