Install Blower
Install Blower Cover
1. Locate blower motor cover.
2. Install strain relief on the blower motor wire.
3. Run the blower motor wires through the small opening
in the blower motor cover.
4. Install the strain relief from step 2 into the blower motor
cover.
5. Reposition the blower motor cover retainer spring
as illustrated.
6. Remove paper from the rear of the rectangular felt pad
and apply adhesive side of felt to the bellow flange.
NOTE: This step is important to ensure maximum blower
performance.
7. Apply blower motor cover to the blower. Slightly spread the
cover retainer spring to allow the cover to drop into position
on the blower motor.
NOTE: Motor wire is on top of motor.
8. Rotate blower motor cover so the bellows are facing
towards the front of the installation.
9. Move blower motor wire to the front of the installation.
10. Remove the cardboard or hardboard from under the range.
11. Remove the front lower access panel of the range by gently
lifting on the panel then pull outward.
12. Using 2 or more people, gently move the range into its final
location.
13. Check to ensure the flexible metal gas connector and
electrical cord are not kinked. Use a flashlight to look
underneath the bottom of the range.
14. Verify that the anti-tip bracket is installed and engaged.
a. Use a flashlight to look underneath the bottom
of the range.
b. Visually check that the rear range foot is inserted
into the slot of the anti-tip bracket.
15. Rotate blower motor cover so the bellows are in their final
position. Ensure the rear of the bellow flange is engaged
in the retaining slots.
16. Use a #2 square drive bit to secure the front of the blower
bellow flange to the range frame with the supplied screw.