Connect Blower Electrical Parts
1. Locate and remove the blower electrical terminal cover
from the lower right side of range. This is located in front
of the blower bellow connection.
2. Locate the capacitor.
NOTE: The capacitor has two posts of 4 terminals.
In this application, there is not a polarity to the capacitor.
Post 1
3. Locate the blower motor wire and find the 2 loose wires
with female push terminals.
4. Install one wire to any terminal of capacitor post 1and then
install the second wire to any terminal of capacitor post 2.
Post 1
5. Locate the capacitor storage tray in front of the blower
bellow connection point in the lower right side of the range.
6. Place capacitor in tray.
7. Locate the 4 wire quick connect terminal on the blower
motor wire and plug it into the terminal connection point
directly behind the capacitor storage tray.
NOTE: The terminal release (clip point) will be facing
toward the front of the range.
18
Post 2
Post 2
8. Install split grommet onto the blower motor wire.
9. Install the split grommet into the U-shaped cutout
of the blower electrical terminal cover. Ensure the groove
of the grommet is properly placed on the terminal cover.
10. Replace blower electrical terminal cover.
NOTE: When replacing cover, insert the terminal cover tabs
in the corresponding slots in the range, and pull the terminal
cover forward to engage.
11. Replace terminal cover screw.
12. Replace the access panel by aligning the studs with the
keyhole slots on the range. Press the access panel forward
into the slots and push downward to engage the studs.
13. Reconnect power.