Cleaning The Unit; Cleaning The Unit With Solvents; Work Or Repairs At The Electrical Equipment; Work At Electrical Components - WAGNER TempSpray-H126 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
safety regulatIons
1.10

cLeaNiNG THe uNiT

Danger of short-circuits caused by water in-
gression!
Never spray down the unit with high-pres-
sure or high-pressure steam cleaners.
1.11

cLeaNiNG THe uNiT WiTH SOLVeNTS

When cleaning the unit with solvents, the
heating of the heating hose has to be switched
off, because an explosive gas/air-mixture can
emerge in the hose. The solvent should never
be sprayed or pumped back into a container
with a small opening (bunghole). An explo-
sive gas/air mixture can arise. The container
must be earthed.
1.12
WOrk Or rePairS aT THe eLecTricaL
equiPMeNT
These may only be carried out by a skilled electrician. No li-
ability is assumed for incorrect installation.
1.13

WOrk aT eLecTricaL cOMPONeNTS

Unplug the power plug from the outlet before carrying out
any repair work.
32
TempSpray-H326 / -H226 / -H126/ -H426
1.14

Max. OPeraTiNG PreSSure

The permissible operating pressure for the spray gun, spray
gun accessories, unit accessories and high-pressure hose must
not fall short of the maximum operating pressure of
25 MPa (250 bar or 3625 psi).
1.15

SeTTiNG

TempSpray-H326 and TempSpray-H226:
Position the heating-hose drum close to the spray-painting
device, without causing a risk of stumbling.
Do not use the heating-hose drum, if the power cord is de-
fect.
TempSpray-H126 and TempSpray-H426:
Assemble the governor housing to an adequate and suffi-
ciently fixed device connection.
Don't use the heating-hose, if the power cord is defect.