Level 3 - ELECTRONIC - Error message example :
E L E C T R O N I C
5 V
P S U :
T O O
Level 3 - ELECTRONIC - OK message example :
E L E C T R O N I C
5 V
P S U :
O K
Level 3 - ELECTRONIC - Error message example :
E L E C T R O N I C
5 V
P S U :
T O O
Level 3 - AUXILIARY - Warining message example :
E L E C T R O N I C
A U X
5 V
P S U :
T O O
Level 3 - AUXILIARY - OK message example :
E L E C T R O N I C
A U X
5 V
P S U :
O K
Level 3 - AUXILIARY - Warining message example :
E L E C T R O N I C
A U X
5 V
P S U :
T O O
Level 3 - DMX DIMMER - Warining message example :
D M X D I M M E R
M O D U L E
D I S C O N N E C T E D
Level 3 - DMX DIMMER - OK message :
D M X D I M M E R
M O D U L E
C O N N E C T E D
X X . X V
L O W
X X . X V
X X . X V
H I G H
X X . X V
L O W
X X . X V
X X . X V
H I G H
EN - 35 -
ELECTRONIC (Level 3)
Statut:
Error : Followspot has stopped
Message:
5 V P S U : T O O L O W
Reason:
Voltage too low: <4,5 V
- If mains voltage used is correct, test Low Voltage
Solution:
on PSU and CPU board
- Change any faulty unit(s)
Statut:
OK: Followspot is working correctly
Message:
5 V P S U : O K
Reason:
Correct voltage range: 4,5 to 5,5 V
Solution:
NA
Statut:
Error : Followspot has stopped
Message:
5 V P S U : T O O H I G H
Reason:
Voltage too high: >5,5 V
- If mains voltage used is correct, test CPU board
Solution:
- Replace the CPU board
AUXILIARY (Level 3)
Statut:
Warning: Followspot can still be used
Message:
A U X 5 V P S U : T O O L O W
Reason:
Voltage too low: <4,5 V
- If mains voltage used is correct, test Low Voltage
Solution:
on PSU and CPU board
- Change any faulty unit(s)
Statut:
OK: Followspot is working correctly
Message:
A U X 5 V P S U : O K
Reason:
Correct voltage range: 4,5 to 5,5 V
Solution:
NA
Statut:
Warning: Followspot can still be used
Message:
A U X 5 V P S U : T O O H I G H
Reason:
Voltage too high: >5,5 V
- If mains voltage used is correct, test CPU board
Solution:
- Replace the CPU board
DMX DIMMER (Level 3)
Statut:
Warning: Followspot can still be used
Message:
M O D U L E D I S C O N N E C T E D
Reason:
Flat cable DSUB25 disconnected in the followspot
Solution:
Connect the flat cable DSUB25
Statut:
OK: Followspot is working correctly
Message:
M O D U L E C O N N E C T E D
Reason:
NA