Level 3 - LIGHT SENSOR - OK message :
L I G H T S E N S O R
L E V E L : 1
Level 3 - BALLAST SENSOR - Error message :
B A L L A S T S E N S O R
B A L L A S T
D E F A U L T
Level 3 - BALLAST SENSOR - Error message :
B A L L A S T S E N S O R
O U T P U T
D E F A U L T
Level 3 - LAMP HOUSE - Error message :
L A M P H O U S E :
M I C R O S W I T C H
O P E N
Level 3 - LAMP HOUSE - Error message :
L A M P H O U S E :
G E N E R A L
O V E R H E A T I N G
Level 3 - LAMP HOUSE - OK message :
L A M P H O U S E :
S A F E T Y
S W I T C H E S :
Level 3 - LENS TUBE - Error message :
L E N S T U B E :
U N P L U G G E D
D S U B 1 5
Statut:
Message:
O K
Reason:
Solution:
BALLAST SENSOR (Level 3)
Statut:
Message:
Reason:
Solution:
Statut:
Message:
Reason:
Solution:
LAMP HOUSE (Level 3)
Statut:
Message:
E R R O R
Reason:
Solution:
Statut:
Message:
Reason:
E R R O R
Solution:
Statut:
Message:
Reason:
O K
Solution:
LENS TUBE (Level 3)
Statut:
Message:
E R R O R
Reason:
Solution:
EN - 30 -
OK: Followspot is working correctly
-
NA
NA
Error : Followspot has stopped
B A L L A S T D E F A U L T
Lamp doesn't turn ON during ignition of the
followspot
Replace the sensor in the power supply unit
Error : Followspot has stopped
O U T P U T D E F A U L T
Lamp turns OFF after ignition of the followspot
- Check that the lamp is correctly in place
- Check the electrical equipment
- Check if PSU is working correctly
Error : Followspot has stopped
M I C R O S W I T C H O P E N
Lamp house cover not correctly mounted
Check that lamp house cover is correctly
positioned into place
Error : Followspot has stopped
G E N E R A L O V E R H E A T I N G
Over heating of the lamp house: >80° C
- Check all sensors
- Ensure fans are working correctly
- Check if lamp is in good condition
- Replace used lamp that may cause over heating
OK: Followspot is working correctly
S A F E T Y S W I T C H E S : O K
NA
NA
Error : Followspot has stopped
U N P L U G G E D D S U B 1 5
The DSUB-15 flat cable in the lens tube is not
connected
Reconnect the DSUB-15 flat cable
EN