Level 3 - IGNITOR (in lamp house) - Error message :
I G N I T O R
I G N I T O R
F A N :
Level 3 - IGNITOR - Error message example :
I G N I T O R :
I G N I T O R
F A N :
Level 3 - IGNITOR - Warning message example :
I G N I T O R :
I G N I T O R
F A N :
Level 3 - IGNITOR - OK message example :
I G N I T O R :
I G N I T O R
F A N :
Level 3 - COLOUR GELS - Warning message example :
C O L O U R G E L S :
C O L O U R S
F A N :
Level 3 - COLOUR GELS - Warning message example :
C O L O U R G E L S :
C O L O U R S
F A N :
Level 3 - COLOUR GELS - OK message example :
C O L O U R G E L S :
C O L O U R S
F A N :
Level 3 - FAN FUSE - Error message :
F A N F U S E
F A N S
F U S E :
B L O W N
D E F A U L T
6 5 7 R P M
T O O
L O W
2 1 1 7 R P M
T O O
L O W
3 2 6 9 R P M
O K
X X X X R P M
D E F A U L T
1 7 5 3 R P M
T O O
L O W
2 1 3 3 R P M
O K
EN - 33 -
FAN - LAMP HOUSE - IGNITOR (Level 3)
Statut:
Error : Followspot has stopped
Message:
I G N I T O R F A N : D E F A U L T
Reason:
Fan not connected
Solution:
Check or replace faulty fan
Statut:
Error : Followspot has stopped
Message:
I G N I T O R F A N : T O O L O W
Reason:
Fan running too slow or is faulty: 1 to 1000 RPM
Solution:
Check or replace faulty fan in the lamp house
Statut:
Warning: Followspot can still be used
Message:
I G N I T O R F A N : T O O L O W
Reason:
Fan running slow or is faulty: 1001 to 3000 RPM
Solution:
Check or replace faulty fan in the lamp house
Statut:
OK: Followspot is working correctly
Message:
I G N I T O R F A N : O K
Reason:
Ignitor fan running correctly: >3001 RPM
Solution:
NA
FAN - COLOUR GELS (Level 3)
Statut:
Warning: Followspot can still be used
Message:
C O L O U R S F A N : D E F A U L T
Reason:
Faulty fan speed sensor and/or fan
Replace the fan's speed sensor or fan in the colour
Solution:
changer compartment
Statut:
Warning: Followspot can still be used
Message:
C O L O U R S F A N : T O O L O W
Reason:
Fan running too slow or is faulty: 1 to 2000 RPM
Check or replace faulty fan in the colour
Solution:
changer compartment
Statut:
OK: Followspot is working correctly
Message:
C O L O U R S F A N : O K
Reason:
Colours fan running correctly: >2001 RPM
Solution:
NA
FAN FUSE (Level 3)
Statut:
Error : Followspot has stopped
Message:
F A N S F U S E : B L O W N
Reason:
Fuse burned out
Solution:
Replace fuse and faulty fan in the lamp house