Level 3 - LENS TUBE - Warning message :
L E N S T U B E :
S A F E T Y
L O O P :
Level 3 - LENS TUBE - OK message :
L E N S T U B E :
C O N N E C T E D
D S U B 1 5
Level 3 - BALLAST - Warning message example :
B A L L A S T :
T E M P E R A T U R E :
Level 3 - BALLAST - OK message example :
B A L L A S T :
T E M P E R A T U R E :
Level 3 - BALLAST - Error message example :
B A L L A S T :
B A L L A S T
O V E R H E A T I N G
Level 3 - BALLAST - Error message example :
B A L L A S T :
T E M P .
S E N S O R
Level 3 - LAMP HOUSE - Warning message example :
L A M P H O U S E :
T E M P E R A T U R E :
Level 3 - LAMP HOUSE - OK message example :
L A M P E H O U S E :
T E M P E R A T U R E :
W A R N I N G
O P E N
O K
2 ° C
T O O
L O W
5 1 ° C
O K
8 5 ° C
X X X ° c
D E F A U L T
3 ° C
T O O
L O W
6 4 ° C
O K
EN - 31 -
Statut:
Warning: Followspot can still be used
Message:
S A F E T Y L O O P : O P E N
Microswitch(s) / thermoswitch(s) open or flat
Reason:
connector(s) unplugged
- Make sure that the lamp house cover is correctly
closed
Solution:
- Check all sensors in the followspot
- Reconnect any unplugged connector(s)
or sensor(s)
Statut:
OK: Followspot is working correctly
Message:
C O N N E C T E D D S U B 1 5
Reason:
NA
Solution:
NA
BALLAST (Level 3)
Statut:
Warning: Followspot can still be used
Message:
T E M P E R A T U R E : T O O L O W
Reason:
Temperature of the PSU too low: <4° C
Place the followspot in an area temperatured
Solution:
between 5° to 79°C
Statut:
OK: Followspot is working correctly
Message:
T E M P E R A T U R E : O K
Reason:
Correct temperature range: 5° to 79° C
Solution:
NA
Statut:
Error : Followspot has stopped
Message:
B A L L A S T O V E R H E A T I N G
Reason:
PSU temperature range not accepted: >80° C
Solution:
Check fans in the power supply unit (PSU)
Statut:
Error : Followspot has stopped
Message:
T E M P . S E N S O R D E F A U L T
- Sensor not connected, check sensor
Reason:
- Check wiring
Solution:
Locate and replace the faulty thermoswitch
LAMP HOUSE (Level 3)
Statut:
Warning: Followspot can still be used
Message:
T E M P E R A T U R E : T O O L O W
Reason:
Temperature in lamp house too low: <4° C
Place the followspot in an area temperatured
Solution:
between 5° to 79°C
Statut:
OK: Followspot is working correctly
Message:
T E M P E R A T U R E : O K
Reason:
Correct temperature range: 5° to 79° C
Solution:
NA
EN