Level 3 - LAMP HOUSE - Error message example :
L A M P H O U S E :
L A M P
O V E R H E A T I N G
Level 3 - LAMP HOUSE - Error message example :
L A M P H O U S E :
T E M P .
S E N S O R
Level 3 - CPU - Warning message example :
C P U :
T E M P E R A T U R E :
Level 3 - CPU - OK message example :
C P U :
T E M P E R A T U R E :
Level 3 - CPU - Error message example :
C P U :
C P U
O V E R H E A T I N G
Level 3 - LAMP HOUSE - Error message :
L A M P H O U S E
M A I N
F A N :
D E F A U L T
Level 3 - LAMP HOUSE - OK message :
L A M P H O U S E
M A I N
F A N :
O K
8 6 ° C
X X X ° c
D E F A U L T
2 ° C
T O O
L O W
5 6 ° C
O K
1 2 4 ° C
EN - 32 -
Statut:
Error : Followspot has stopped
Message:
L A M P O V E R H E A T I N G
Lamp house temperature range not accepted:
Reason:
>80° C
Solution:
Check fans in the lamp house
Statut:
Error : Followspot has stopped
Message:
T E M P . S E N S O R D E F A U L T
- Check all sensors in the followspot
Reason:
- Reconnect any unplugged connector(s)
or sensor(s)
Solution:
Locate and replace the faulty thermoswitch
CPU (Niveau 3)
Statut:
Warning: Followspot can still be used
Message:
T E M P E R A T U R E : T O O L O W
Reason:
Temperature of the CPU in PSU too low: <4° C
Place the followspot in an area temperatured
Solution:
between 5° to 79°C
Statut:
OK: Followspot is working correctly
Message:
T E M P E R A T U R E : O K
Reason:
Correct temperature range: 5° to 110° C
Solution:
NA
Statut:
Error : Followspot has stopped
Message:
C P U O V E R H E A T I N G
Reason:
CPU temperature range not accepted: >110° C
Solution:
Check fans in the power supply unit (PSU)
FAN - LAMP HOUSE (Level 3)
Statut:
Error : Followspot has stopped
Message:
M A I N F A N : D E F A U L T
Reason:
Driver fan has stopped working
Solution:
Replace faulty fan and/or driver
Statut:
OK: Followspot is working correctly
Message:
M A I N F A N : O K
Reason:
NA
Solution:
NA