ENGLISH
and lift the module carefully from
the motor head.
Attach the clock module to the
base provided, push the provided
seal
underneath
above the contact block and
press down as far as possible.
Put the pre-assembled module
into the contact chamber block of
the motor head, press it in secur-
ely. Ensure that the module is in
the correct position. Place the
earthing bar in the appropriate
opening (E · ) and screw in the
earthing screw. Screw the two
fastening screws alongside (E · )
and in the openings which are still
empty on the base. Tighten them
with a screwdriver.
Place the capacitor in the terminal
box cavity. Position the capaci-
tor's connecting wires in such a
way that they can easily be put
into the two tip jacks (-
the wires neatly. Pass the network
cable through the PG threaded
joint and connect to the terminals
L, N, and the earthing screw (E · ).
Tighten PC screw once again.
Position the module lid supplied
with the assembly set. Position
and tighten the fastening screws.
– Switch on mains supply again.
6 Starting up/Settings
Module can be operated by the
user!
10
the
module
| |
- ) Position
The preset time is set using the
adjustable strips on the rim of the
switch clock between
– pump mode (red area visible)
– pump shut-down (red area not
visible)
Setting the preset time (Fig. 10):
Open the transparent lid carefully
with a screwdriver.
– for the operating times, press the
adjustable strips on the rim of the
switch clock radially towards the
centre
(1 adjustable strip =
hour),
– Synchronise the switch clock with
the correct time of day. In order to
do so, turn the turn the rim of the
clock clockwise until the correct
time is directly under the arrow
marking.
Close transparent lid.
Subject to technical alterations!
1
/
4